Audina CUE Скачать руководство пользователя страница 5

touch, double touch or cover and touch.
Your hearing healthcare professional will
program the instrument during your initial
fitting for the style of touch you prefer.

1

2

These digital hearing instruments have
been custom made for your ears; they
should fit comfortably and easily. When
preparing to insert the instrument into your
ear, position it so the white dot is at the top
and the pull string is at the bottom. Your
hearing healthcare provider will provide 
instruction on proper insertion and removal.

Inserting Your Digital Hearing Instrument

Your digital hearing instruments are
equipped with a low battery indicator with 
a unique acoustic fade feature. When the
battery in your hearing instrument is low,
you will hear a series of warning tones a
few minutes before the battery goes dead.
It is recommended that you install a fresh
battery at this time.

To replace your hearing instrument battery, 
follow these steps:

Step 1:

Lift the notch at the edge of the battery 
compartment and swing open the door. 
Remove the used battery. 

Battery Information

To turn your hearing instrument “on”, you
simply need to close the battery door after
inserting a battery. To turn your hearing 
instrument “off”, open the battery door
completely. This will disengage the battery
and turn off the hearing instrument.  

In fact, when the hearing instrument is not
in use, it is recommended that you open
the battery door and remove the battery.
This helps to prevent excessive battery
drain and allows for proper ventilation of
the hearing instrument.

On/Off Function

With a simple touch to your ear, SoftTouch
allows you to change memories for up to
four different listening environments. Your
Cue instrument may be set for a single

SoftTouch

Technology

025 Cue Instruction Manual:Layout 1  3/31/11  9:19 AM  Page 9

Содержание CUE

Страница 1: ...nts ExclusiveSoftTouch Technology DiscreetCustomFit ExtremelyComfortable Hearing Healthcare Provider Made in U S A P O Box 877 Casselberry FL 32718 0877 audina net I N S T R U C T I O N M A N U A L 025 Cue Instruction Manual Layout 1 3 31 11 10 12 AM Page 1 ...

Страница 2: ...TotallyInvisible CustomHearing Instruments 025 Cue Instruction Manual Layout 1 3 31 11 9 19 AM Page 3 ...

Страница 3: ...s to precisely fit your hearing and communication requirements If necessary your hearing healthcare provider may make further modifications to enhance your listening experience A period of adjustment may be needed to become accustomed to your new hearing instruments and the renewed world of sounds you will experience The adjustment time varies for each individual and may be as little as a couple o...

Страница 4: ...7 Care and Storage 8 Do s and Don ts 9 Troubleshooting 11 Binaural Amplification 13 Serial Numbers 14 Warranty Information 15 Service and Repair Information 17 Children with Hearing Loss 18 Notice to Perspective Users 19 Notice to Healthcare Providers 20 Owner Information 22 Table of Contents 025 Cue Instruction Manual Layout 1 3 31 11 9 19 AM Page 7 ...

Страница 5: ...ead It is recommended that you install a fresh battery at this time To replace your hearing instrument battery follow these steps Step 1 Lift the notch at the edge of the battery compartment and swing open the door Remove the used battery Battery Information To turn your hearing instrument on you simply need to close the battery door after inserting a battery To turn your hearing instrument off op...

Страница 6: ...al When your hearing instruments are not in use open the battery compartment to prevent excessive battery drain and ventilate the instruments Important Always discard used batteries Small batteries can be harmful if swallowed Keep batteries out of the reach of pets and small children In case of ingestion contact your physician or call the National Button Battery Hotline at 202 625 3333 Step 3 Swin...

Страница 7: ...aring aid immunity to the rating for the cell phone emissions For example the sum of a hearing aid rating of 2 M2 T2 and a telephone rating of 3 M3 T3 would result in a combined rating of 5 Any combined rating that equals at least 5 would provide normal use a combined rating of 6 or greater would indicate excellent performance The immunity of this hearing aid is at least M2 T2 The equipment perfor...

Страница 8: ...ot use cotton swabs to clean your ears due to the risk of pushing the wax deeper into the ear canal Cleaning Your Hearing Instrument Hearing instruments are exposed to moisture in the form of humidity and perspiration while being worn The daily use of a dehumidifying system or drying kit approved by your hearing healthcare provider is recommended These accessories may be purchased from your hearin...

Страница 9: ...s The Do s and Don ts of Hearing Instruments Do remove your hearing instruments if you are going to have X rays at your dentist or medical facility It is best to keep them outside the room of the X ray equipment Don t leave your hearing instruments on the radiator near a stove in a sunny window in a car or in any other hot place Excessive heat and cold can damage the instruments Don t wear the hea...

Страница 10: ...s and large vents can cause whistling Contact your hearing healthcare provider Sound is Distorted or Unclear Replace the battery Hearing instruments may have a poor battery contact or may not be programmed properly Return to your hearing healthcare provider Intermittent Sound Replace the battery Ensure that there is no wax or debris in the sound channel Hearing instruments may have a poor battery ...

Страница 11: ...size and feature sophisticated electronics that accommodate a wide variety of hearing losses Nature gave us two ears for a reason and since the majority of people who have a hearing loss are affected in both ears two binaural hearing instruments are typically recommended Two hearing instruments should provide these benefits Better overall sound quality when compared to one hearing instrument stere...

Страница 12: ...ologic needs proper fitting and adjustments by your hearing healthcare provider and proper use by the owner Any implied warranty shall be limited to one year from date of purchase The only entity or individual who is authorized to perform the warranty obligations is the manufacturer All in house warranty work performed by the manufacturer will be Warranty Information done within a reasonable perio...

Страница 13: ...Casselberry FL 32718 0877 You must include your current phone number and home address There is a 40 charge to cover shipping and handling Please include a check payable to Audina Hearing Instruments Inc for said amount when sending your instruments for service Service and Repair Information It is recommended to purchase shipping insurance when sending your hearing aids to the manufacturer If your ...

Страница 14: ... restricts the sale of hearing instruments to those individuals who have obtained a medical evaluation from a licensed physician Federal law allows a fully informed adult to sign a waiver statement declining the medical evaluation for religious or personal beliefs that preclude consultation with a physician The exercise of such a waiver is not in your best interest and its use is strongly discoura...

Страница 15: ...cial care should be exercised in selecting and fitting a hearing instrument which has a maximum sound pressure level in excess of 132 dB decibels because there may be a risk of damaging the remaining hearing of the hearing instrument user Owner Information MODEL SERIAL NUMBERS LEFT RIGHT PURCHASE DATE BATTERY SIZE ORIGINAL WARRANTY EXPIRES HEARING HEALTH CARE PROVIDER 025 Cue Instruction Manual La...

Страница 16: ...23 Notes 025 Cue Instruction Manual Layout 1 3 31 11 9 19 AM Page 31 ...

Отзывы: