Audicus Aura Скачать руководство пользователя страница 4

6

A

Microphone

 

– where sound enters your hearing aid

B

Battery door

 

  open to insert and remove size 10 battery,

used to turn on and off the device

C

Pullstring 

– pull to remove device from the ear

D

Dome

 

–  white hypoallergenic silicone cover  to hold the unit 

in place comfortably in the ear canal

Earwax guard

 

–  (under dome) prevents earwax from 

entering device

Your hearing aid

at a glance

A

 

(microphone)

B

 

(battery door)

C

 

(pullstring)

D

 

(dome)

E

 (earwax guard,

     under dome)

7

Turning on / off

Do not dispose of batteries in household trash

Keep away from high temperature, children and pets

Do not place batteries in your mouth; if swallowed, 

consult a physician

door closed = ON

10 zinc-air
– yellow tab

IEC: PR70 |  ANSI: 7005ZD

Battery size

1.

Gently  swing  open  the  battery  door  with  your 
fingernail  and  push  out  the  old  battery.  Do  not 
open the battery door too far or damage can occur

2.

Remove the plastic tab from the new battery, 

wait 

2-3 minutes

 for the battery to activate

3.

Insert  the  battery  carefully  into  the  small  holder. 
Line up the battery’s plus "

+

" sign (flat side of the 

battery) with the colored dot  on the battery door

4.

If the door will not close easily, ensure the battery 
is not inserted upside down. 

Do not force closed

5. Low battery indicator:

 aid will double beep when 

there  is  30  minutes  of  battery  life  remaining

Содержание Aura

Страница 1: ...The Aura CICHearingAid InstructionManual ...

Страница 2: ...ide to get the most out of your custom tailored Audicus Aura Completely In Canal CIC hearing aid Audicus is with you every step of the way Find more info and videos at audicus com support And remember you re never on your own Reach out anytime for anything at all 917 999 0705 contact audicus com ...

Страница 3: ... 10 carrying case earwax guards domes small large extra medium on device hearing aid s cleaning brush with magnet Getting Started pages 4 9 Using The Aura pages 12 21 Troubleshooting pages 10 11 Contents Device Information pages 22 27 ...

Страница 4: ...re children and pets Do not place batteries in your mouth if swallowed consult a physician door closed ON 10 zinc air yellow tab IEC PR70 ANSI 7005ZD Battery size 1 Gently swing open the battery door with your fingernail and push out the old battery Do not open the battery door too far or damage can occur 2 Remove the plastic tab from the new battery wait 2 3 minutes for the battery to activate 3 ...

Страница 5: ...ther hand as you push the hearing aid in If the device does not fit you may try another dome size 4 To remove gently grasp the pullstring with your thumb and index finger and pull away slowly 9 Volume change To make the device louder A Cup your hand slightly B Quickly double tap your ear with the cupped palm Device beeps on volume change Two beeps for volume level 2 etc 1 2 3 4 Volume level C Repe...

Страница 6: ...icus Low volume Increase the volume See page Volume change Each ear must be quickly tapped twice with a closed palm to change the volume 11 Beeping Cause Remedy Low battery Multiple double beeps indicates low battery voltage Change battery Feedback Whistling Cause Remedy Hand or clothing near device Move hand clothing away from device Poorly fitting dome Try a new dome size See Finding the right d...

Страница 7: ...e using the hearing aid 13 The dome should fit snugly in your ear canal If missized you may hear feedback a squealing or whistling sound that can be resolved with a different dome size You can order replacement domes by calling Audicus or visiting audicus com care Record your preferred dome size here Dome size Clean your domes regularly Replace old brittle discolored or damaged domes or if they pu...

Страница 8: ...nd quality is diminished Your order comes with a blue case containing 8 yellow sticks each with an earwax guard attached 15 C To dispose of the used earwax guard insert the removal end of the tool into the tip of the hearing aid Carefully pull straight out to remove the earwax guard Do not twist when removing D Ensure the earwax guard is removed and a new one is visible at the insertion end of the...

Страница 9: ...ur devices or replace components more frequently Never use cleaning agents such as detergent soap alcohol or bleach to clean your hearing aid Do not submerge your hearing aid or rinse your hearing aid under water 17 Audicus Care All the products needed to care and maintain your device are available at audicus com accessories Audicus Care is the easiest way to get everything you need to maintain yo...

Страница 10: ...e using hair spray spray paint or any other sticky sprays that can clog the microphone Keep hearing aids away from children and pets Cats and dogs frequently chew on hearing aids if left unattended often beyond repair 19 Audicus Protect and Repairs Your hearing aid comes with a 12 month manufacturer s warranty Additional repairs may incur costs depending on the severity Accidents happen The Audicu...

Страница 11: ...aring aid ships with a size medium dome attached with additional dome sizes separate Use the Finding the right dome guide if you have any discomfort or hear feedback whistling sound 21 3 It may take a few weeks to get used to the feel of your hearing aid Contact Audicus any time for guidance and tips to help adjust comfortably 4 Your aid is programmed to your specific hearing test it may take time...

Страница 12: ...se your hearing aid all day long The best way to ensure better hearing is to practice listening with your hearing aid until you are able to wear it comfortably all day Generally infrequent use of the hearing aid does not provide you with the full benefit of amplification Your hearing aid will not restore normal hearing Hearing aids will not prevent or improve hearing impairment resulting from a ph...

Страница 13: ...ect the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the device into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 25 Operating conditions This device is designed such that it functio...

Страница 14: ...e conditions that may affect hearing are identified and treated before the hearing aid is purchased 27 Following the medical evaluation the physician will give you a written statement that states that your hearing loss has been medically evaluated and that you may be considered a candidate for a hearing aid The physician will refer you to an audiologist or a hearing care professional as appropriat...

Страница 15: ...rev 21A audicus com 917 999 0705 contact audicus com ...

Отзывы: