OVERVIEW 

The CU402/X is the central unit of the AASER system. The 
AASER  system  is  a  revolutionary  solution  to  have  a 
controlled  sound  emission  with  a  constant  polar  pattern 
with  high  directivity  and  for  the  entire  audio  spectrum. 
The  polar  pattern  opening  could  be  regulated  from  120 
to  180  degrees.  The  central  unit  include  the  power  and 
the  DSP  section,  has  the  main  control  interface  and  the 
audio  connections.  Through  an  USB  connection  is  it 
possible  to  connect  the  device  to  a  PC  and  make 
advanced  configurations  with  the  AASER-GUI  software 
(you can download the software from website or require it 
to  an  authorized  distributor).  The  system  has  two 
balanced  inputs,  one  pass-through    output,  one  power 

output for the AASER projector and a amplified output for 
reinforcement speaker if needed.  
 
One of the input in connected to the output, the second is 
not  connected  to  the  output,  this  allow  you  to  have  in 
cascade systems some sound only in one section.  
You  can  connect  more  projector  in  the  same  CU  by  the 
expansion box sold separately. 
 

FRONT PANEL 

In the front panel is located: 
(1)

 

VU METER, this METER indicate the input sound level, 
regulate the gain in the source to have a level that use 
all the dynamic but in the red limit of the METER. 

 

 

 
 
(2)

 

Red  LED  that  indicate  an  overload  on  the  amplifier 
modules,  restart  the  device  if  this  is  on  and  reduce  the 
sound level. 

(3)

 

Main  volume  regulation,  this  KNOB  regulate  the  output 
level of the amplifier section 

(4)

 

Aux  volume,  this  KNOB  regulate  the  gain  of  the  AUX 
amplified  channel,  the  power  of  this  channel  is  600W 
RMS ad 4 ohm. 

Pay  attention,  put  this  KNOB  at  the  minimal 
volume and increase the volume progressively to 
not damage the connected speakers. 

(5)

 

Power on switch 

(6)

 

Program push button for CU device programming, more 
information in the software user manual. 

 

REAR PANEL 

In the rear panel there are all the connection interface. 
Following the details: 
(1) The power supply inlet (speakon) 
(2) Aux powered output (600 watt). 2 pole speakon type 
connector 
(3)  AASER  projector  connection,  8  pole  speakon 
connector 
(4)  USB  plug  for  PC  connection.  Use  AUDEIA  AASER-
GUI software for device programming. 
(5) Line pass-through output, XLR balanced line  
(6) Line pass-through input, XLR balanced line 
(7) Line input (not in pass-through), XLR balanced line

 

 

 

 

The  power  supply  inlet  and  the  power  supply  specifics  change  according  to  countries  standards;  until  to 
connect the AC cord to the power source please verify that the supply voltage and frequencies printed on the 
rear panel are coincident with the local electrical system specifics. 
 

 

 

CONNECTIONS  

 

Содержание CU402

Страница 1: ...MNCU402x R02 EN AUDEIA CU402 x AASER Central Unit USER MANUAL Revision 0 2016 February EN www audeia com ...

Страница 2: ...of fire or electric shock do not expose this apparatus to rain or moisture Only use attachments accessories specified by the manufacturer Refer all servicing to qualified personnel To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so Servicing is required when the apparatus has been damaged in an...

Страница 3: ...AUTION SIMBOLS 2 SAFETY INSTRUCTIONS 2 DISPOSAL OF ELECTRICAL AND ELECTRONIC EQUIPMENT 2 INCLUDED ITEMS 4 ABOUT THIS MANUAL 4 LEGAL DISCLAIMER 4 PRECAUTION FOR INSTALLATION AND USE 4 WARRANTY 4 OVERVIEW 5 FRONT PANEL 5 REAR PANEL 5 TECHNICAL SPECIFICS 7 ...

Страница 4: ...nificant vibration exposed to direct sunlight in extremely hot places in places with high humidity or bad ventilation places exposed to rain or other water Do not place anything on the unit Do not expose to fast reduction of temperature because condensation could occur with possible damaging of the apparatus If this happen leave the unit for one or two hours before turning the unit on Avoid instal...

Страница 5: ...source to have a level that use all the dynamic but in the red limit of the METER 2 Red LED that indicate an overload on the amplifier modules restart the device if this is on and reduce the sound level 3 Main volume regulation this KNOB regulate the output level of the amplifier section 4 Aux volume this KNOB regulate the gain of the AUX amplified channel the power of this channel is 600W RMS ad ...

Страница 6: ...3 Negative The powered output are speakon type In the AUX line output the pole 1 is the positive the pole 2 is the negative REAR HOLDER SUPPORT To simplify the mounting in standard rack mount chassis the system is equipped with a adjustable flange Make a measuring of the depth in the chassis adjust the position of the flang 2 according the measure and fix the 4 screws 1 ...

Страница 7: ...f channel xxxx4 stereo Connector xxxx3 5mm TRS jack ANALOGICAL LINE OUTPUTS Number of channel xxxx4 stereo Connector xxxxx3 5mm TRS jack USB INTERFACE Connector type B type USB AUDIO PERFORMANCES Frequency response 20Hz 33kHz 0 1 dB 1W 8Ohm S N Ratio input Analog min 115dB Crosstalk separation 85 dB 1 kHz Input sensitivity 8Ω 3 Vrms 11 7 dBu THD N DIM100 0 08 from 0 1 W to full power typically 0 0...

Страница 8: ...www audeia com ...

Отзывы: