![AUDAC MTX Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/audac/mtx/mtx_user-manual_3007047004.webp)
4
SVx
Set output volume of a zone to a level
Command: SVx, with x the zone where the volume should be changed.
Arguments: Volume in neg db, 0 is maximum volume, 70 is minimum volume
Example
Set volume in zone 2 to -40dB
Command
#|X001|web|SV2|40|U|return
Answer
#|web|X001|SV2|+|U|return
Update
#|ALL|X001|V02|40|7378|return
SVU0x
Set volume up with 3dB
Command: SVU0x, with x the zone where the volume should be changed.
Arguments: 0 (none)
Example
Current is Volume -30db, set volume up with 3dB in zone 1
Command
#|X001|web|SVU01|0|U|return
Answer
#|web|X001|SVU01|+|U|return
Update
#|ALL|X001|V01|27|U|return
SVD0x
Set volume down with 3dB
Command: SVD0x, with x the zone where the volume should be changed.
Arguments: 0 (none)
Example
Current volume is -27db, set volume down with 3dB in zone 1
Command
#|X001|web|SVD01|0|U|return
Answer
#|web|X001|SVD01|+|U|return
Update
#|ALL|X001|V01|30|U|return
SRx
Set routing in a zone (select input)
Command: SRx, with x the zone where the routing should be changed.
Arguments: input (0-8)
Example
Select Line 3 as input for zone1
Command
#|X001|web|SR1|3|U|return
Answer
#|web|X001|SR1|+|U|return
Update
#|ALL|X001|R01|3|3dc5|return
SRU0x