background image

 

1

 

Operation Instruction Manual 

WS-1500EBPM 

Precision PID Temperature Controller

 

Version 1.1 

Auber Instruments 

5755 North Point Parkway, Suite 99 

Alpharetta, GA 30022 

770-569-8420 

www.auberins.com 

May, 2013 

Introduction 

Thank you for purchasing the Auber WS series temperature controller. We sincerely 
appreciate your decision and trust that our machine will meet your expectations in both 
the quality of the result and the value of our product. While we are delighted that you may 
be anxious to operate the controller for your project, a few minutes of your time reading 
through this manual will only serve to enhance your experience in the months and years 
ahead. In particular, we urge you to read through the safety warnings below. Although 
this plug-and-play controller is very easy to operate, the process involves high 
temperature and high wattage appliances, and your safety is paramount. 

 SAFETY WARNINGS 

 

  This controller is designed only to be used with devices that have limited power 

and their own thermal cutoff protection, such as a thermostat or thermal fuse in 
case of controller failure.   

  Do not place any objects on the top of controller surface which is used to vent 

excess heat during its operation.   

  The maximum electric current this controller can handle is 15 Ampere. For 120 

volt AC in US and Canada, this limits the heater power to 1800 watts. Due to its 
compact size and the splash proof design for kitchen applications, the controller 
has a limited ability to dissipate the heat generated by the internal solid state relay 
during the initial heat up. The initial full power heat up process cannot be more 
than 90 minutes. If you system need take longer time to warm up, please read 
Appendix 1 “Managing the heat generated by the controller

” 

 

Always place the sensor in the controlled subject when the controller is on.

 

Before turning on the controller, please make sure the sensor is placed inside the 
container to be controlled. Leaving the sensor outside will form an open loop 

Содержание WS-1500EBPM

Страница 1: ...ETY WARNINGS This controller is designed only to be used with devices that have limited power and their own thermal cutoff protection such as a thermostat or thermal fuse in case of controller failure...

Страница 2: ...he controller off unplug the power cord and contact the manufacturer before using it again Clean the controller only when it is cool and unplugged Do not allow children to operate the controller Speci...

Страница 3: ...ht on the cooking device 3 SET Key For showing current temperature settings entering parameters setting mode and confirming various actions taken 4 Key To increment displayed value 5 Key To decrement...

Страница 4: ...Figure 2 Back Panel 2 Connecting the controller Figure 3 Typical connection between the controller and the heating device in this example the cooker The connection of the controller should be done in...

Страница 5: ...heater has a switch put it in the off position Put the sensor inside the container to be controlled Turn on the controller Turn on the heating device Remark The connector of sensor contains a slot fo...

Страница 6: ...erature may not be able to reach the current step temperature setting before it jumps to the next step The time unit is in minutes with 1 minute resolution If the recipe only needs one step you can pr...

Страница 7: ...steps for cooking you can finish programming by pressing the SET continuously until it passed T06 and the LED displays the current temperature You can also leave the controller alone The display will...

Страница 8: ...to use these settings for other cooking device also because they are suitable for a typical slow response and balanced system If you feel the performance is not ideal you can try to use the recommend...

Страница 9: ...66 Symbol Display Description Range Initial P P Proportional band in 0 1 Degree 0 600 180 I I Integral constant second 0 900 700 d d Derivative constant second 0 300 40 AT AC Auto tune 0 off 1 on 0 T...

Страница 10: ...cookers setting I 0 will significantly reduce the temperature overshoot d Derivative time The unit is in seconds Derivative action contributes the output power based on the rate of temperature change...

Страница 11: ...ng environment The duration of auto tuning depends on how fast the system is responding to the heating and cooling cycle If the temperature of the cooker takes a long time to drop when the heater is o...

Страница 12: ...ED displays LCK Then release the SET key The display will show 0 To get into parameters setting mode you need to key in the pass code Use and keys to adjust the display to 166 which is the pass code a...

Страница 13: ...cooling 0 heat 1 cool 0 Out 00t Output power reduction 1 100 100 C F C F Temperature unit C or F C 180 0 AL AL Alarm Setting 58 0 392 0 F 50 0 200 0 C Details about each parameter SC calibration offs...

Страница 14: ...eater with a one litter 1 qt pot of water at 130 F The heater is too powerful for the small water volume The moment it is on it releases too much energy and overshoots the temperature Although it is s...

Страница 15: ...n its value Use and keys to change the setting When finished press the SET again to confirm the change For example if the temperature is 1 C too high during calibration then use to set the value to 1...

Страница 16: ...andling in transit This warranty does not cover damage or defects caused by or resulting from damages from shipping or repairs service or alterations to the product or any of its parts which have been...

Страница 17: ...17 ATTENTION CUSTOMER SERVICE We are constantly striving to improve our products and therefore the specifications contained herein are subject to change without notice...

Страница 18: ...l produce about 1 3 watts of heat When 12 Amp is passing through the controller 16 watt of heat is produced in the controller As more heat is produced the temperature inside the controller will rise I...

Страница 19: ...ive current is much lower making heat not an issue 2 Limit maximum output power If you set output reduction parameter to 80 then a 15A heater will become a 12A heater It will take 25 longer time to he...

Отзывы: