Страница 1: ...ty The wide blade should go to the wide slot 4 Connecting the Controller Note 1 Set Temperature There are two ways to set the target temperature a During the normal operation mode press Λ or V once to switch the display from process value PV to set value SV or target temperature The display will start to blink Press Λ or V again to increase or decrease the SV When finished wait 8 seconds and the s...
Страница 2: ... configuration parameter setting PSb 0 rd 0 CorF 0 C 1 F End Code Setting Range Initial Note Inty K outy 2 inty Atdu Hy 3 Description outy hy atdu psb rd corf end Input Sensor Type Control Output Mode Hysteresis Band Autotune Offset Input Offset Control Function Display Unit Exit See Appendix 0 1 2 3 4 5 6 0 9999 0 200 1000 1000 0 heating 1 Cooling 10 1 Note 9 Note 10 Note 11 Note 13 Note 14 Figur...
Страница 3: ...F 200 1300 C 320 2400 F Appendix 1 Table 4 Other types of thermocouple and their code that can also been used with this controller Figure 8 Auto tuning Fan on Start When heating Outy 6 If PV SV Hy relay on If PV SV relay off SV 100 Hy 3 Figure 10 Limit control mode PV SV SV Hy 100 97 PV SV SV Hy 100 97 Fan on When heating and outy 3 If PV SV Hy relay on If PV SV relay off SV 100 Hy 3 Figure 9 On o...
Страница 4: ......