background image

 

11 

 

C-2= 290, F-2=160; 
C-3=130, F-3=30.0. 
You can leave the rest of steps as their default values.   
 
To store in program to recipe b1, long press SET key, set LoCK=2, choose b1, and press SET 
again to confirm and exit. Now the controller is back to the normal operating mode. It will run on 
this current program, which has just been saved as recipe b1.   
 

8.2  Recall a recipe to the current program (Program Mode) 

Before you input your program, check the PrG = on (accessed by LoCK code “3”). Long press 
SET, set LoCK=2, choose b1, press set to exit. 
Then  recipe  b1  is  recalled  back  as  the  current  program.  The  controller  is  back  to  the  normal 
operating mode and will start run the current program.   
 

8.3  Store your program as recipe (Single-step Mode) 

Before you input your set temperature, check the PrG = off (accessed by LoCK code “3”).   
Press SET key once, and then set C-1=150, press set again to confirm and exit. The controller 
will go back to the normal operating mode and start running on this single-step program.   
 
To store current program back to recipe b2, long press SET, set LoCK=2, choose b2, press set to 
confirm and exit. Now your current program is stored as recipe b2. 
 

8.4  Recall your recipe to current program (Single-step Mode) 

Before you input your set temperature, check the PrG = off (accessed by LoCK code “3”).   
Long press SET, set LoCK=1, choose b2, press set to confirm and exit. 
Now the C-1 from the recipe b2 is recalled back to your current program. The controller will start 
run at this temperature setting.   
 

8.5  Advanced examples 

This example will show you how the PrG mode can affect the saved and current recipe/program.   
 
1) Set PrG = on, select “b1” recipe: 
C-1=120, t-1=2.0; 
C-2= 290, F-2=160; 
C-3=130, F-3=30.0; 
 
2) Change PrG=off, now the current single-step program is:   
C-1: 120. 
 
3) Set current C-1 to 200, then store current program back to recipe b1. Now the b1 recipe is: 
C-1: 200. 

Содержание WS-1211GPH

Страница 1: ...s designed only to be used with limited power device and paring thermal cutoff protection such as a thermostat or thermal Do not place any objects on the top of controller surface because that may pre...

Страница 2: ...nly Using it to control a not recommended device can be dangerous and even cause fire Auber Instruments is not liable for damages caused by misuse of the controller If you are not sure the controller...

Страница 3: ...4 Key To increase the value at parameter setting mode toggle LED display between the current temperature and the current step number at normal operating mode 5 Key To decrease the value at parameter...

Страница 4: ...cted to the power strip by the 16 AWG power cord supplied blue arrows The generator is connected to the power strip by the power cord from Bradley green arrows The controller output is connected to th...

Страница 5: ...or by the power jumper cord provided by the Bradley blue arrows It is the cord that used to connect the generator to smoker The controller output is connected to the smoker by the power cord red arrow...

Страница 6: ...r t is displayed as the symbol T Time is defined as the duration between the last step and the next step Please make sure the time is long enough for the heater to heat up the oven If the time is set...

Страница 7: ...me in the current step using the Time or key Please see the flow chart in Figure 5 080 10 P 2 Time Total operating time since power up Press once Press once Operating time on current step P 1 Press on...

Страница 8: ...s vide cooking For details on how to access these parameters please check section 5 of the main instruction manual 5 1 The first group of parameter is related to the control performance They need to b...

Страница 9: ...These recipes can be stored in the memory of the controller even when it is powered off You can overwrite the exist recipe with a new one For details on how to access these parameters please check sec...

Страница 10: ...ecall a recipe press and hold SET key for 3 seconds until the Parameter Window displays LOCK Release the SET The display will show 0 Use and keys to adjust the display to 3 and press SET The display w...

Страница 11: ...e and then set C 1 150 press set again to confirm and exit The controller will go back to the normal operating mode and start running on this single step program To store current program back to recip...

Страница 12: ...show 0 then Use key to adjust the number to 666 and press SET key again to confirm The display will show as lnlE then it will show as off Press key once to change off to on Press SET key to confirm fa...

Отзывы: