TH220A TEMPERATURE AND HUMIDITY CONTROLLER  

INSTRUCTION MANUAL   

Version 1.3 (May, 2019) 

 

1.

 

Overview 

This plug-n-play temperature and humidity controller is designed for high 
relative humidity (>85%) and condensing environments, where slight 
temperature drop may cause condensation and could damage the sensor. This 
controller equipped with one of the most robust humidity sensors on the 
market. It can be fully recovered even immersed in water. Ideal for curing 
Fridge. The controller can control both temperature (heating or cooling) and 
humidity (humidifying or dehumidifying) at the same time.

 

 
2.

 

Specifications 

Temperature Control Range 

- 40°C ~ 80°C, - 40°F ~ 176°F 

Temperature Resolution 

0.1°C (between -9.9°C ~ 80°C) 
1°C (between -40°C ~ 10°C) 
0.1°F (between -9.9°F ~ 99.9°F) 
1°F (between -40°F ~ 10°F,100°F ~176°F) 

Temperature Accuracy 

0.5°C  

Temperature Control Mode 

On/Off Control. Heating or Cooling 

Temperature Control Output 

15 A, 120 V or 240 V AC * 

Humidity Control Range 

0 ~ 99.9% RH 

Humidity Resolution 

0.1% RH 

Humidity Accuracy 

4% RH 

Humidity Control Mode 

On/off control.  
Humidifying or dehumidifying 

Humidity Control Output 

15 A, 120 V or 240 V AC * 

Operating Temperature 

0°C ~ 50°C  

Dimension  

91 x 140 x 46 mm  

Input Power  

85 ~242 V AC, 50 Hz / 60 Hz  

Sensor Cable Length  

6 ft (2 m)  

Power Cable Length  

3 ft (1 m)  

Please note

: Although both temperature and humidity output can handle up to 15A, the 

combined total power of the two channels are limited to 15A due to the limitation of input 
power cord.  

 
 

3.

 

Front Panel 

 

Figure 1. Front Panel. 

Measured temperature window: 

In normal operating mode, this window 

shows measured temperature. In parameter setting mode, this window shows 
parameter name.

 

Measured humidity window: 

In normal operating mode, this window shows 

measured humidity. In parameter setting mode, this window shows parameter 
value.  

Alarm indicator:

 When the alarm is muted, the alarm indicator (the small dot 

on the last digit) will be on. 

 

SET key

: Access the program settings and parameter settings. 

UP key (Unmute)

: Increase the value. Press down momentarily to unmute the 

alarm. 

DOWN key (Mute)

: Decrease the value. Press down momentarily to mute the 

alarm. 

Temperature socket

: Supply power to heater/cooler. 

Temperature indicator

: Red LED indicator; it is on when the temperature 

socket is energized. 

Humidity socket

: Supply power to the humidifier/dehumidifier. 

Humidity indicator

: Green LED indicator; it is on when the humidity socket is 

energized. 

 
 

4.

 

Getting Started 

4.1 Power up the controller and connect the sensor 

To power up the controller, simply plug its power plug to a wall outlet. Then 
connect the 4-pin connector from the humidity sensor to the sensor input port 
on the bottom of the controller. Please align the notch on the sensor plug with 
the key on the sensor socket. You can refer to the Section 6 in the manual for 
details.  
 

4.2 Displayed Information 

The top LED window displays the measured temperature, and the bottom LED 
window displays the relative humidity reading. If sensor is not connected or 
defective, the controller will show “

ERR

” in its display window.  

 
There is one LED indicator on each side of the controller to show the output 
status of each output socket. The red LED on the left is for the temperature-
control socket, and the green LED on the right is for the humidity-control 
socket.     
 

4.3 Decide the Control Mode for Each Output Socket 

The temperature-control socket can be set either to drive a heating device or to 
drive a cooling device. This temperature-control mode is determined by the 
parameter 

tCM

 (

tCM

), which can be set to “

Ht

” for heating, or “

CL

” for 

cooling.   
 
Similarly, the humidity-control socket can be set either to drive a humidifying 
device or to drive a dehumidifying device. This humidity-control mode is 
determined by the parameter 

hCM

 (

hCM

), which can be set to “

H

” for 

humidifying, or “

DeH

” for dehumidifying.   

 