background image

  AUBER INSTRUMENTS

    

 

 

     

 

 

 

             

WWW.AUBERINS.COM  

 

2017.10                                                                                                                                                                                                          P1/3

 

 

 

TH220 TEMPERATURE AND HUMIDITY CONTROLLER  

INSTRUCTION MANUAL   

Version 1.2 (Oct, 2017) 

 

1.

 

Overview 

This plug-n-play temperature and humidity controller is designed for high 
relative humidity (>85%) and condensing environments, where slight 
temperature drop may cause condensation and could damage the sensor. This 
controller equipped with one of the most robust humidity sensors on the 
market. It can be fully recovered even immersed in water. Ideal for curing 
Fridge. The controller can control both temperature (heating or cooling) and 
humidity (humidifying or dehumidifying) at the same time.

 

 
2.

 

Specification 

Table 1. Specifications 

Temperature Control Range 

- 40 ~ 80 ° C, - 40 ~ 176 ° F 

Temperature Resolution 

0.1 ° C (between -9.9 ~ 80 ° C) 
1 ° C (between -40 ~ 10 ° C) 
0.1 ° F (between -9.9~99.9 ° F) 
1 ° F (between -40 ~ 10 ° F,100 ~176 ° F) 

Temperature Accuracy 

0.5 ° C  

Temperature Control Mode 

On/Off Control. Heating or Cooling 

Temperature Control Output 

15A, 120V or 240V AC * 

Humidity Control Range 

0~99.9% RH 

Humidity Resolution 

0.1% RH 

Humidity Accuracy 

4% RH 

Humidity Control Mode 

On/off control.  
Humidifying or dehumidifying 

Humidity Control Output 

15A, 120V or 240V AC * 

Operating Temperature 

0~50 ° C  

Dimension  

91x140x46mm  

Input Power  

85 ~242VAC, 50Hz/60Hz  

Sensor Cable Length  

6 ft (2m)  

Power Cable Length  

3 ft (1m)  

* Please note: Although both temperature and humidity output can handle up to 
15A, the combined total power of the two channels are limited to 1500 Watts 
due to the limitation of input power cord.  
 

3.

 

Front Panel 

Up Key,Unmute Alarm
Dn Key, Mute Alarm

Set Key

Heating/

Cooling 

Device Socket

Humidifier/
Dehumidifier
Device Socket

Humidifier/Dehumidifier
On Indicator

Heating/Cooling 

Device On Indicator

Measured

Humidity

Measured

Temperature

Alarm Indicator, On 
when Alarm Muted

Sensor Socket

 

Figure 1. Front Panel 

Measured temperature window: 

In normal operating mode, this window 

shows measured temperature. In parameter setting mode, this window shows 
parameter name.

 

Measured humidity window: 

In normal operating mode, this window shows 

measured humidity. In parameter setting mode, this window shows parameter 
value.  

Alarm indicator:

 When the alarm is muted, the alarm indicator (the small dot 

on the last digit) will be on. 

 

SET key

: Access the program settings and parameter settings. 

UP key (Unmute)

: Increase the value. Press down momentarily to unmute the 

alarm. 

DOWN key (Mute)

: Decrease the value. Press down momentarily to mute the 

alarm. 

Temperature socket

: Supply power to heater/cooler. 

Temperature indicator

: Red LED indicator; it is on when the temperature 

socket is energized. 

Humidity socket

: Supply power to the humidifier/dehumidifier. 

Humidity indicator

: Green LED indicator; it is on when the humidity socket is 

energized. 

 

4.

 

Setup Flow Chart 

When the controller is powered on, it will display the measured  
temperature and humidity. The controller will keep running according to the 
saved setting. If the humidity or temperature sensor is shorted/disconnect, the 

controller will display “Err”. Please see Figure 2

 and 3 for the flow chart to set 

the parameters. 

 

5.

 

Parameter Settings 

To change the target temperature or humidity, press SET key momentarily. 
The controller will show tSP (temperature set point), press SET again will show 
HSP (humidity set point). Use Up or Down key to change the tSP or HSP. See 
Figure 2 for details.  
 
To change the other parameters, press SET key for 3 seconds, the RH window 
(bottom window) will show tE, Hu or SYS* (depending on which menu was set 
last time). tE menu is for temperature control settings; Hu menu is for humidity 
control settings and SYS* is for system settings. Press Down (or Up) key to 
change the RH window to Hu (or tE, SYS), which is the current selected menu, 
then press SET key to enter. 
 
To change parameter settings, in the parameter setup mode, use Up or Down 
key to modify the parameter value. Then press SET key again to confirm the 
change. This instrument will automatically exit if no key is pressed for 10 
seconds.  Please see the Table 1 for the parameters. 
 

* Menu SYS and parameter PSD are only applicable for TH220-W model.  

 
 
 
 

Instruction Manual

 

 

Отзывы: