background image

         AUBER INSTRUMENTS

  

 

 

 

 

 

 

 

         WWW.AUBERINS.COM  

 

 

         2020.04                                                                     

   

                                                       P2/2 

 

3.4.1

 

Standard Mode 

When the controller is powered up in standard mode or switched to standard 
mode, the top display will show “

std

” briefly.  

 
This  controller  has  been  programmed  for  100  Watt  hot  runner  coil.  The  set 
temperature has been set to 300

°

F. If you want to change the set temperature, 

please follow the steps below: 
 
1) Press down the knob briefly. The decimal point in the lower right corner of 
the bottom display will start flashing.  
2)  Turn  the  control  knob  to  adjust  the  set  temperature.  Turn  it  clockwise  to 
increase the value; counter-clockwise to decrease the value. Use fast rotation 
action for big adjustment, use slow rotation action for single digit adjustment.   
3)  Press  down  the  knob  again  to  confirm  the  new  set  temperature.  The 
controller  will  also  exit  the  editing  mode  if  the  knob  was  untouched  for  10 
seconds. 
 

3.4.2

 

Boost Mode 

In a boost mode, the user can quickly cycle between two set temperatures, a 
lower standby temperature and a higher boost temperature, by simply pressing 
down the control knob. There is no need to turn the knob back and forth to 
adjust for the desired set temperature. 
 
To switch from the standby temperature to the boost temperature, simply press 
down the control knob. The lower display will show the new set temperature, 
which is the boost temperature. To switch back to the standby temperature, 
press down the knob again.  
 
There are 3 boost modes available, named as “

b-1

”, “

b-2

”, and “

b-3

”. A user 

can adjust and save customized standby temperature and boost temperature 
for each mode. By default, the standby temperature is 300°F and the boost 
temperature is 550°F for all three boost modes.        
 
When the controller is powered up in a boost mode or switched to a boost 
mode, the top display will show the name of the boost mode briefly and then 
show the coil temperature. The bottom display will show the standby 
temperature.   
 
More detailed explanation of the boost mode and the related parameters can 
be found in the RDK-300B Supplementary Manual.  
  

3.4.3

 

Switching Between Standard Mode and Boost Mode 

To change the operating mode, turn the control knob in any direction for at 
least a half turn (180°) in one action to bring up the mode-selecting menu. The 
top window will show “

MOD

” and the bottom window will show the name of 

the current mode. Turn the knob slowly in either direction to browse the options 
in the menu and press down the control knob to confirm your selection. The 
flashing dot in the lower right corner indicates the item is in editing and has not 
been saved yet.  
 
 

3.5

 

Advanced Parameter Settings 

Please see the RDK-300B Supplementary Manual for more information about 
parameters.   
 
 
(End) 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Auber Instruments Inc. 

5755 North Point Parkway, Suite 99, 

Alpharetta, GA 30022 

www.auberins.com 

E-mail: [email protected] Tel: 770-569-8420 

 

Copyright 2007-2020, Auber Instruments All Rights Reserved. 

No part of this manual shall be copied, reproduced, or transmitted in any way without the prior, written 

consent of Auber Instruments. Auber Instruments retains the exclusive rights to all information 

included in this document. 

 