MEMORY PROTECTION
The programmable switch is equipped with a rechargeable battery that
will protect your program recordings during a power failure.
Note that the screen is not ON during power outage.
CHARACTERISTICS
Model:
TI054A-06-3W
Supply:
240 VCA, 50 / 60 Hz
Load:
15 watts min., 500 watts max.
Approvals :
CE
Storage temperature range:
-20 to 50°C
Operating temperature range: 0 to 50 *C
Max. latitude :
+/- 65°
Precision of the solar table:
+/- 11 min. (max. error near the Poles)
WARRANTY
AUBE TECHNOLOGIES INC. ONE YEAR LIMITED WARRANTY
This product is warranted against material defects and workmanship in
normal use for a period of one year, from the date of the original pur-
chase from authorized dealers. Warranty does not cover transportation
costs. Nor does it cover a product subjected to misuse or accidental
damage.
This limited warranty is in lieu of all other warranties, obligations or lia-
bilities expressed or implied by the company.
In no event shall AUBE Technologies inc. be liable for consequential or
incidental damages resulting from installation of this product. Within
this period, any product proven defective in normal use will be repaired
or replaced, at AUBE's option, without charge for either parts or labour,
provided that the defective product with the original sale receipt is
returned to the original dealer or is shipped pre-paid, insured and
addressed to:
Head Office:
Aube technologies inc.
705, Montrichard
10 rue Ampère
Iberville (Quebec)
95500 Gonesse
Canada J2X 5K8
France
Tel.: (450) 358-4600
Tel.: 33 (0) 1 34 07 99 06
Fax: (450) 358-4650
Fax: 33 (0) 1 34 07 99 19
www.aubetech.com
www.aubetech.com
Carrer Segur, 74
08035 Barcelona
España
Tel.: 34 93 420 28 73
Fax: 34 93 429 30 79
www.aubetech.com
920-054-001-00-1-0 3/3
DEFINING YOUR PROGRAMS
1- This switch can memorize 2 “ON/OFF” programs which repeat
themselves every day.
If you have entered your city’s parameters, the programs “P1 ON” and
“P2 OFF” represent sundown and sunrise hours. Our example shows
these results.
If your switch is set at “AUTO”, your lights will go on at sundown and go
off at sunrise.
2- If you wish your lights to go on at sundown but go off for example at
23:00, enter program “P1 OFF - 23:00”.
Furthermore, if you wish your lights to go back on at 5:00 AM and go
off at sunrise, enter program “P2 ON - 5:00”
Note that the “P1 OFF” and “P2 OFF” programs have priority on the “P1
ON” and “P2 ON” programs respectively.
If, for example, the sun rises at 4:58 (“P2 OFF”) and you request in “P2
ON” that the lights go on at 5:00, the lights will not go on that morning.
3- If you wish to replace the “sundown” and/or “sunrise” programs by a
fixed hour, select the “P1 ON” or “P2 OFF” programs and enter new
parameters using the HOUR and MIN buttons.
nor
- Standard time
- Winter time
Ad
- Daylight-saving time
- Summer time
SAVING YOUR PROGRAMS
1- Press on the PGM button to select the program.
2- Use the HOUR and MIN buttons to modify the program.
3- Press on the CODE button to return to the initial value.
P1 ON = Sundown
P1 OFF = -- : --
P2 ON = --:--
P2 OFF = Sunrise
4- Press on the SAVE button to record your modifications and return
to the MANUAL or AUTOMATIC operating mode.
TO SWITCH FROM STANDARD TIME TO
DAYLIGHT-SAVING TIME
If your country uses daylight-saving time, execute the following proce-
dure when the time changes:
1- Press 4 times on the CODE button to select the “nor/Ad” mode.
2- Use the MIN button to switch from the “nor” (Standard) mode to the
“Ad” (Daylight-saving) mode and vice versa.
3- Press on the SAVE button to return to the MANUAL or AUTOMATIC
operating mode.
The programmable switch will automatically adjust the clock and the
sundown/sunrise table for the period of the year. You do not need to
adjust the clock manually.
LAT
LONG
ATHENS
GREECE
37
23
39
22