The TI035 programmable wall switch has been designed to control lightings and motors:

NOTE

: This switch cannot be used if there are not at least 2 white wires joined by a 

connector inside the electrical box.

1)

Cut power at the circuit breaker to avoid electric shock.

2)

Remove the existing switch.

3)

Install the new switch.

4)

Apply power at the circuit breaker.

Applications

Load type

Maximum load

Examples

Resistive load

2400 W 
(20 A @ 120 V)

• incandescent lights
• halogen lights
• block heater

Inductive load

2400 W 
(20 A @ 120 V)

• fluorescent lights
• compact fluorescent lights (CFL)
• sodium lamps
• electronic ballasts

Motor

1 hp

• pool filter pumps
• fans

Installation

120 VAC (line)

white (neutral)

black (line)

blue (load)

Load

TI035

Installation and User Guide

Programmable Wall Switch

69-2776EF-03

Содержание TI035

Страница 1: ...ing switch 3 Install the new switch 4 Apply power at the circuit breaker Applications Load type Maximum load Examples Resistive load 2400 W 20 A 120 V incandescent lights halogen lights block heater I...

Страница 2: ...m number are displayed To temporarily override bypass the programmed schedule briefly press the switch door The new state ON or OFF will flash to show that this state is temporary The override remains...

Страница 3: ...might switch On Off too early or too late with respect to sunrise and sunset Therefore apply a correction factor 1 or 1 Otherwise leave it at 0 Programming the sunset sunrise parameters Once you have...

Страница 4: ...times Select program P1 ON or P2 OFF and enter the desired time using the HOUR and MIN buttons 3 Press one of the control buttons or close the switch door to return to normal operation Clearing a prog...

Страница 5: ...TED TO THE THREE YEAR DURATION OF THIS WARRANTY Some provinces states or regions do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warran...

Страница 6: ...KANSAS CITY 39 94 0 KNOXVILLE 35 83 1 LAKEWOOD 39 105 0 USA CITY LAT LONG Lc LANSING 42 84 1 LAREDO 27 99 1 LAS VEGAS 36 115 0 LEXINGTON 38 84 1 LINCOLN 40 96 0 LITTLE ROCK 34 92 0 LONG BEACH 33 118...

Страница 7: ...pteur existant 3 Installer le nouvel interrupteur 4 Remettre le circuit sous tension partir du disjoncteur Applications Type de charge Charge maximale Exemples Charge r sistive 2400 W 20 A 120 V clair...

Страница 8: ...e marche arr t ON ou OFF sont affich s Mode automatique L interrupteur suit l horaire programm Le mode AUTO l tat de marche arr t ON ou OFF et le num ro du programme en cours sont affich s Pour d roge...

Страница 9: ...175 3 nor Ad Si votre pays a l heure avanc e s lectionner la p riode actuelle de l ann e 4 Lc Si le fuseau horaire de votre ville est bas sur des fronti res politiques ou conomiques plut t que sur se...

Страница 10: ...ouvez remplacer les heures du lever du soleil et du coucher du soleil par des heures fixes S lectionner les programmes P1 ON ou P2 OFF et enregistrer les heures d sir es en utilisant les touches HOUR...

Страница 11: ...IE Certaines provinces ou r gions ne permettent pas de limiter la dur e des garanties tacites et par cons quent la pr sente limitation peut ne pas s appliquer La pr sente garantie donne au consommateu...

Страница 12: ...CITY 39 94 0 KNOXVILLE 35 83 1 LAKEWOOD 39 105 0 TATS UNIS VILLE LAT LONG Lc LANSING 42 84 1 LAREDO 27 99 1 LAS VEGAS 36 115 0 LEXINGTON 38 84 1 LINCOLN 40 96 0 LITTLE ROCK 34 92 0 LONG BEACH 33 118 0...

Отзывы: