background image

TI033

      400-033-001-C                    30/11/06                    1/2

TI033

Installation and User Guide

Programmable Wall Switch

The TI033 programmable wall switch has been designed to control
lightings and motors:

NOTE

: This switch cannot be used if there are not at least 2 white

wires joined by a connector inside the electrical box.

n

Cut power at the circuit breaker to avoid electric shock.

o

Remove the existing switch.

p

Install the new switch as shown in the diagram below.

q

Apply power at the circuit breaker.

n

Pry the switch door open from the 
bottom using a small screwdriver.

o

Ensure the 

ON/OFF

 selector is set 

to ON.

p

Reset the switch using a paper clip. 

0:00

 and 

MO

 will flash.

If the display is blank:

Ensure the 

ON/OFF

 selector is properly engaged in the 

ON

 posi-

tion. Push it to the right using a small screwdriver.

NOTE

: The switch displays the time in 24-hour format by default or

following a reset. 

n

To change to 12-hour format (or vice versa),  proceed as follows:
a) Press one of the control buttons to ensure the 

MAN

 or 

AUTO

 indicator is displayed.

b) Press  the 

MIN

 and 

HOUR

 buttons simultaneously and brief-

tly (

0:00

 display = 24-hour, 

12:00

 display = 12-hour ).

o

Set the time using the 

HOUR

 and 

MIN

 buttons. If you have 

selected the 12-hour format, ensure that 

PM

 appears on the 

screen when an afternoon time is displayed.

p

Set the day by using the 

DAY

 button.

q

Press one of the control buttons or close the switch door to 
return to normal operation.

The programmable switch has 2 operating modes: manual (

MAN

)

and automatic (

AUTO

).  To switch mode, press the switch door for 3

seconds.

Manual Mode

The programmable switch operates as a regular
switch. Briefly press the switch door to turn the lights
On or Off. The mode (

MAN

)

 

and state (

ON

 or 

OFF

)

are displayed.

Automatic Mode

The programmable switch follows the programmed
schedule.  The mode (

AUTO

), state (

ON

 or 

OFF

)

and current program number are displayed.
To temporarily override the programmed schedule,
briefly press the switch door. The new state 

(

ON

 or 

OFF

)

 will flash to

show that this state is temporary. The override remains in effect until
you press the switch door again or until the beginning of the next
program.

You can set up to 7 programs. To set a program, you need to enter its
start time (

ON

) and its end time (

OFF

).

n

Pry the switch door open using a small screwdriver.

o

Press the 

PGM

 button to display a program and 

its On or Off time. For example, when you first 
press 

PGM, 

program number 1 (

P1

) and its On 

time (

ON

) will appear. 

- : - -

 will appear instead 

of the time if the program is not set (inactive).

p

Press the 

DAY

 button to select the day to which 

you want to apply the program.

NOTE

: If you want to apply the program to 

every day of the week, press 

DAY

 until all the 

days are displayed. (This still counts as 1 program, not 7)

n

Applications

1.

Load type

Maximum load Examples

Resistive load

2400 W 
(20 A @ 120 V)

incandescent lights

halogen lights

block heater

Inductive load

2400 W 
(20 A @ 120 V)

fluorescent lights

compact fluorescent lights (CFL)

sodium lamps

electronic ballasts

Motor

1 hp

pool filter pumps

fans

o

Installation

2.

p

Power-On

3.

120 VAC

white (neutral)

black (line)

white

black

white

black

blue

Control (4)

Reset

On/Off
selector

q

Setting the Clock

4.

r

Selecting the Operating Mode

5.

s

Programming

6.

400-033-001-C ENG (print at 90%).fm  Page 1  Thursday, November 30, 2006  8:50 AM