22
PARTS –
CONTINUED
WIRING GUIDE
Wire Hook Up to Quick Disconnect
Black = - 12 Volt Ground
Yellow = + 12 Volt Shoot Up
Red = + 12 Volt Shoot Down
Blue = + 12 Volt Shoot Left
Green = + 12 Volt Shoot Right
Brown = Spare
Switch Kit
1. Place hand control in cab with enough extra cable so you can move around for use.
2. Run white and black wires back to battery so the white and black wires will reach the battery.
3. Now run the remaining wires to the front of the machine following the loader arms.
4. Cut wire to length and hook up to female quick disconnect.
5. Mount female quick disconnect near auxiliary hydraulic lines, use mounting plate included in box.
6. Connect wires from attachment to male end of quick disconnect.
7. Make sure the color wires from the female side match up with the color wires from the male side.
8. Connect black and white wires to battery, (black is negative, white is positive).
9. You are now ready to test the functions of the blower, to do so
auxiliary hydraulics will have to be on and
running
.