ATX Q series Скачать руководство пользователя страница 5

          Q-Series

®

 Amplifi ers – QPAIR Redundant Amplifi er System – Installation & Operation Manual 

1-1

CHAPTER 1: DESCRIPTION OF INTERFACES

DESCRIPTION OF INTERFACES

1.  Description of Interfaces

The QPAIR system (the system) has fi ve sections: two modular amplifi er sections, the RF switch section and two replaceable 

power supplies.

Replaceable Power Supplies:

 (one located at each end of the chassis)

AC Input (100-240 VAC, 50 or 60 Hz) or -48 VDC input.
The system can also be ordered with (1) AC input and (1) 48 VDC input for source redundancy.
The power supply confi guration depends on user specifi cation at time of ordering.

Description:

 Both of the power supplies are connected at the same time via their designated terminals. In normal operation, 

the power supplies are in redundant mode with no switching required. Power supply 1 and power supply 2 each have a green 

LED (PWR 1 and PWR 2) on the front to indicate normal power supply operation. The PWR Failure red LED (see Figure 1) on 

the front also indicates power supply status. If the PWR Failure LED is solid red, then that indicates the PWR1 supply is not 

operational and if the LED is blinking, then that indicates the PWR 2 supply is not operational. This may also be noted during 

the installation when only one power supply is initially plugged into source voltage. The PWR Failure LED will either be solid or 

blink depending on which power supply is connected to source power fi rst. The PWR Failure LED will remain lit after any PS 

failure or source power failure. Failure is also detected upon unplugging either power supply from the power source. Anytime 

the PWR failure LED is lit and voltage has been restored, or immediately after installation, the RESET button must be pushed 

to activate normal operation.

RF Amplifi er Connections:

 (Rear View)

a) 

Rear of Chassis:

 this section only describes the amplifi er connections, not the switch connections.

Input to AMP 1 (labeled RF IN and located immediately at the lower left of the left heat sink).
Output from AMP 1 (labeled RF OUT and located at the upper right of the left heat sink).
Input to AMP 2 (labeled RF IN and located immediately at the lower left of the right heat sink).
Output from AMP 2 (labeled RF OUT and located at the upper right of the right heat sink).

b) 

Front of Chassis:

 (with cover removed):

RF test point (-20 dB) located at left front of each amplifi er module and labeled “AMP1 OUTPUT TP” on AMP 1 and 

“AMP2 OUTPUT TP” on AMP 2. A Pad socket for input level and pad socket for output level adjustment is located in 

each amplifi er compartment. The equalizer socket for input level and equalizer socket for output level adjustment are 

also located in each amplifi er compartment.

Description:

 The primary and the secondary amplifi er are identical. However, this system designates AMP 1 as the 

primary 

amplifi er

 and AMP 2 is designated as the 

secondary amplifi er

. When we discuss the term 

primary amplifi er

, we are discussing 

AMP 1 and when we use the term 

secondary amplifi er

, we are discussing AMP 2. The primary amplifi er is located approximately 

at the middle of the chassis and the secondary amplifi er is located toward the left side of the chassis from a front view. Each 

QPAIR Redundant Amplifi er System Front View

QPAIR Redundant Amplifi er System Rear View

Содержание Q series

Страница 1: ...INSTALLATION OPERATION MANUAL QPAIR Redundancy Switch Amplifier System www atxnetworks com www atxnetworks com Q SERIES Amplifiers ...

Страница 2: ...lOn Series MAXNET HFC Enhance PCI Filters Q Series FiberLinx are registered trademarks of ATX in the United States and or other countries SMACSM is a service mark of ATX in the United States and or other countries Products or features contained herein may be covered by one or more U S or foreign patents Other non ATX product and company names in this manual are the property of their respective com...

Страница 3: ...nual i TABLE OF CONTENTS Page 1 DESCRIPTION OF INTERFACES 1 1 2 DESCRIPTION OF OPERATION 2 1 3 SET UP PROCEDURE 3 1 4 SPECIFICATIONS 4 1 4 1 Amplifier Specifications 4 1 4 2 Switch Specifications 4 1 5 SERVICE SUPPORT 5 1 5 1 Contact ATX Networks 5 1 5 2 Warranty Information 5 1 ...

Страница 4: ...ii Q Series Amplifiers QPAIR Redundant Amplifier System Installation Operation Manual This page left intentionally blank ...

Страница 5: ...ected upon unplugging either power supply from the power source Anytime the PWR failure LED is lit and voltage has been restored or immediately after installation the RESET button must be pushed to activate normal operation RF Amplifier Connections Rear View a Rear of Chassis this section only describes the amplifier connections not the switch connections Input to AMP 1 labeled RF IN and located i...

Страница 6: ...l level is approximately 25 dB lower than the signal level feeding the primary amplifier FROM AMP 1 Connect the output of the primary amplifier AMP1 to this port FROM AMP 2 Connect the output of the secondary amplifier AMP2 to this port RF OUT on left side of chassis and on the right side of the port labeled FROM AMP 2 This is the main output of the QPAIR system Installation Description 1 If you a...

Страница 7: ...ence levels Normal on power up or reset Flashing 3 sec fast switched to the secondary amplifier when pushing and holding the FORCED SW button Red LED Failure On continuous primary amp failure Signal has been switched to the secondary amplifier by the system Flashing 1 sec slow secondary amp failure Flashing 3 sec fast input signal low or primary amp and secondary amp failure Red LED PWR Failure On...

Страница 8: ...1 4 Q Series Amplifiers QPAIR Redundant Amplifier System Installation Operation Manual CHAPTER 1 DESCRIPTION OF INTERFACES This page left intentionally blank ...

Страница 9: ...eration push the RESET button and then push the SET REF button If the system is running on the primary amp and the secondary amp level is down 3 dB or more the system considers the secondary amp failed and will set the alarm and set the red LED flashing slowly You need to troubleshoot or replace the secondary amplifier See Appendix 3 for troubleshooting instructions or Appendix 2 for replacing the...

Страница 10: ...2 2 Q Series Amplifiers QPAIR Redundant Amplifier System Installation Operation Manual CHAPTER 2 DESCRIPTION OF OPERATION This page left intentionally blank ...

Страница 11: ... chassis 11 Insert Change the proper pad and equalizer so the output levels of the amplifier AMP 1 are correct 12 Push the SET REF button 13 Connect signal strength meter to the OUTPUT TEST POINT of AMP 2 on the front of the chassis 14 Push and hold the FORCED SW button to force a switch to the secondary amplifier AMP 2 15 Insert Change the proper pad and equalizer so the output levels of the ampl...

Страница 12: ...ads on the standoff of the circuit board These screws are located in the center of the board Do not remove the Phillips screws that hold the hybrid module in place Only loosen the 2 knurled thumbscrews in the horizontal centerline of the board Now you should be able to pull up on the screws to free the board from the push on connectors You will then need to tilt the board as you remove it so as to...

Страница 13: ...screw is located on the front of the power supply The screws on the top and bottom are located on the tab of the power supply enclosure where it fastens to the chassis The front screw goes through the front plate of the QPAIR Just remove these 5 screws and then hold the power supply as you locate the 2 wires connecting to the chassis Just unplug the wires from their sockets and the power supply re...

Страница 14: ...ets and Studs on Power Supply Connection Figure 6 QPAIR Block Diagram QPAIR Redundant Amplifier System TO AMP 1 RF INPUT TO AMP 2 FROM AMP 1 RF OUTPUT FROM AMP 2 AMP 1 IN AMP 1 OUT AMP 2 IN AMP 2 OUT NC NO NC NO PAD EQ PAD EQ PAD EQ PAD EQ 20 dB OUTPUT T P 20 dB OUTPUT T P AMP 1 AMP 2 RF SENSING SWITCH DETECTOR DETECTOR CONTROL ...

Страница 15: ...20 1 16 260 40 0 78 75 4 PP GaAs QPAIR1000 19GP 40 1000 19 1 1 5 5 Pad EQ 20 1 16 375 40 0 77 73 5 GaAs PD QPAIR1000 23GP 40 1000 23 1 1 5 75 Pad EQ 20 1 16 375 40 0 77 73 4 GaAs PD QPAIR870 19GPH 40 870 19 1 1 5 5 Pad EQ 20 1 16 440 40 0 82 77 5 GaAs PDH QPAIR1000 19GPH 40 1000 19 1 1 5 5 Pad EQ 20 1 16 440 40 0 81 75 5 GaAs PDH QPAIR1000 23GPH 40 1000 23 1 1 5 75 Pad EQ 20 1 16 440 40 0 81 75 4 ...

Страница 16: ...4 2 Q Series Amplifiers QPAIR Redundant Amplifier System Installation Operation Manual CHAPTER 4 SPECIFICATIONS This page left intentionally blank ...

Страница 17: ... factory RF Products MAXNET SignalOn HFC Enhance PCI Filters Q Series SCN SMAC FiberLinx TECHNICAL SUPPORT Tel 905 428 6068 press 3 then press 2 Toll Free 800 565 7488 press 3 then press 2 USA Canada only Email rfsupport atxnetworks com CUSTOMER SERVICE ATX Networks 1 501 Clements Road West Ajax ON L1S 7H4 Canada Tel 905 428 6068 press 1 Toll Free 800 565 7488 press 1 USA Canada only Fax 905 427 1...

Страница 18: ... ON L1S 7H4 Canada Tel 905 428 6068 Toll Free 800 565 7488 support atxnetworks com ISO 9001 15 REGISTERED 2018 ATX Networks Printed in Canada Information in this document is subject to change without notice www atxnetworks com Rev 07 18 ANW0837 ...

Отзывы: