STATUS MONITORING FEATURES
4. Status Monitoring Features
4.1. SNMP Parameters
MAXNET
®
II – MPRFA/B RF Detector A/B Switch Manual – Installation & Operation Manual
4-1
CHAPTER 3: STATUS MONITORING
CHAPTER 4: STATUS MONITORING FEATURES
Table #4: Common Module SNMP Parameters
Display Name
Description
HMS MIB Variable
Model
ATX model number (note, in empty slots you can enter
passive, dual-passive, or empty to populate the overview
page with passive picture placeholders).
entPhysicalModelName
Description
Description of the module.
entPhysicalDescr
Name
Indicates the slot of the chassis the module is in.
entPhysicalName
Alias
Optional user defined field - added to fifth variable
binding of traps and emails
e.g. set this to “Node 69” for a given Receiver and any
alarms generated by this receiver will have “Node 69”
in the description. Otherwise, it would only contain the
IP address of the chassis, the Model and Name (slot
number).
entPhysicalAlias
Manufacturer
ATX
entPhysicalMfgName
Asset I.D
Optional user settable field (suggestions: enter in a
custom serial number or purchase order # for tracking).
entPhysicalAssetID
Serial No
Module’s serial number.
entPhysicalSerialNum
Hardware Rev
Hardware rev of module.
entPhysicalHardwareRev
Firmware Rev
Firmware rev of module.
entPhysicalFirmwareRev
Temperature [C]
Module’s current heatsink temperature.
heCommonTemperature
Alarm Detection Control
detectionEnabled: normal operation, with active alarms
detectionDisabled: used to temporarily disable alarms/
traps from this module
detectionEnabledandRegenerate: enter
detectionEnabled state while regenerating all alarm table
entries
heCommonAlarmDetectionControl