ATX breez GreenBuilder ATX FAN 100-12v Скачать руководство пользователя страница 2

MODEL: 

ATX FAN 100-12v 

Page 2. 

 

(V) 

3. CONNECT WIRING 

3-1. Follow all local electrical and safety codes, 
ANSI/NFPA70. 

3-2. NEVER place a switch where it can be reached 
from a tub or shower. 

3-3. Connect wires as shown in wiring diagrams 
below and at the bottom right. 

DIMENSIONS 

 

 
 
 
 
 
 

10 

3/4

"

 

 

  

10 

3/4

 

 

4" DUCT

 

 

1" 5 

3/4

 

 
 
 
 
 
 

1/4

"

 

 

 

  

SPECIFICATIONS 

 

Model No. 

Voltage

 

Frequency 

(Hz) 

Power 

@ 0.1SP 

(W) 

Air Flow 

@ 0.1SP 
(CFM) 

Weight 

(lb.) 

 

 

USING HANGER BAR 

1-3.  Sliding hanger bars available to allow for your 
specific positioning of housing anywhere between joists 
and span up to 

24’’.

 

1-4.  Insert hanger bars into the channels on housing. 
Make sure tabs face 

‘‘up’’

 shown. 

 
 
 

 

 

3-5. 18 AWG  is the smallest conductor that shall be 
used for branch-circuit wiring. 

4. TEST RUN & GRILLE ATTACHMENT 

4-1.  When the power on, check for abnormal vibration 

or sound. 

4-2. Insert the mounting springs into the slots and 

mount the grille to the fan unit. 

ATX FAN  
100-12v 

12  

N/A 

10 

100 

5.6 

Note: Design and specifications subject to change without notice. 

 
 
 

 

1-5.  Extend hanger bars to the width of the joists. 
Hold fan in place with the hanger bars tabs wrapping 
around the bottom of joist. 

1-6.  Fasten hanger bars to joists with nails or screws 
through holes near nails. 

1-7.  Secure hanger bars together with screws. 

 

2. DUCT CONNECTION 

2-1.  Insert the duct into the duct connector and tape 
all ductworks connection to make them secure and air 
tight. 

2-2.  Install the duct with a gradient 1°~2° to the 
outside. 

 

Inside Outside

 

 

5. OPERATION 

5-1. Turn on the power switch to operate ON or OFF, 

and LED indicator is green. 

6. MAINTENANCE 

WARNING: 

Disconnect power source before working on unit. 
Routine maintenance must be done every year. 

CAUTION: 

1.

 

Never use gasoline, benzene, thinner or any other 
such chemicals for cleaning the ventilating fan. 

2.

 

Do not allow water to enter motor. 

3.

 

Do not soak resin parts in water over 140°F (60°C). 

CLEANING

 

1.

 

Pull down the spring to remove grille. 

2.

 

Wash and clean grille. (Use non-abrasive kitchen 

Duct Connector

 

 

Body

 

 

 

Tape

 

 

 

Duct

 

 
 
 
 

 

Gradient 

1°~2°

 

detergent, wipe dry with new cloth.) 

3.

 

Using a cloth dampened with non-abrasive 
kitchen detergent, remove dust and dirt from 
ventilating fan. Wipe dry with new cloth. 

4.

 

Replace grille. 

Ceiling

 

Slots 

Grille 

Spring 

Screw

 

Joist

 

Joist

 

Screw 4×25

 

Joist

 

Screw 4×25 

Joist 

 

Hanger Bar

 

 
 
 
 
 
 

Channel

 

3/4

"

 

Grille

 

  

 