Atwood HYDRO FLAME 8935 Скачать руководство пользователя страница 5

5

8900-III AC WIRING

5

BLACK

BLUE

RED

YELLOW

HIGH TENSION

+ 12V DC

NEG

RED

YELLOW

ELECTRODE

YELLOW

VALVE

RED

+THERMO

MOTOR

CIRCUIT

BREAKER

IGNITION

BOARD

BLW PWR

SAIL

SWITCH

BLUE

BLUE

LIMIT

SWITCH

WHITE

BLUE

YELLOW

RED

GROUND

THERMOSTAT

ON

OFF

ON/OFF

SWITCH

  THERMO

RED

IMPORTANT:

 If any original wire has to be replaced, it must 

 

be replaced with type 105 C or its equivalent.

                       Terminal Block on 85 Models only.

CUSTOMER SUPPLIED WIRE

8900-III DC WIRING

5

  12V  DC  

SUPPLY

PICTORIAL DIAGRAM

SCHEMATIC DIAGRAM

Off

On

Valve

Electrode

Green

Sail
Switch

Green

Yellow

3 3

2 2

1 1

White

Black

Yellow

Black

Black

Yellow

Red

Blue

Blue

Limit Switch

Blue

Red

Green

Yellow

Transformer

Ignition Control

Black

Brown

Motor

120 VAC Green

120 VAC Black

120 VAC White

White

Thermo Blue

AC Capacitor Motor Run

+Thermo Blue

HIGH TENSION

IMPORTANT 

If any original wire has to be replaced, it must bereplaced with the type 105 C or its equivilant.

t

t

White

Black

24 VAC

TF

CAP

MOT

3

2
3

SS

LS

IG

PS

TH

R

L1

IND

GND

HV

V1

P/S

GV

EL

DO NOT

GRIP

HERE

1

4

2

3

+

+

1 2 3 4 5 6

HV   =  High Voltage 

PS   =   IG Power Input

GND  =  Ground 

SS   =   Sail Switch

GV   =  Gas Valve 

TH   =   Thermostat

EL   =  Electrode 

LS   =   Limit Switch

IG  

=  Egnition Control 

CAP  =   Capiacitor

MOT  =  Blower Motor 

P/S   =   Power Switch On/Off

IND   =  IG Blower Motor Output 

TF   =   Transformer

 

 

 

V1   =   Valve Control

GND

Gr
een

White

Black

120VAC

NOTE: DC Models only

ON/OFF Switch may be sep-
arate or combined in Circuit
Breaker.

A

Valve Assembly

(Vanne)

Valve Conversion

(Vanne de conversion)

6

Содержание HYDRO FLAME 8935

Страница 1: ...REPLACEMENT PARTS LIST DRAWING 7 SPECIFICATIONS W C Water Column MODEL 8935 8940 8935 8940 DCLP III DCLP III ACLC III ACLC III BTU Input 35 000 40 000 35 000 40 000 Output BTU HR 27 300 31 200 27 300...

Страница 2: ...ANSI A255 1 and or CAN CSA Z240 MH Series Mobile Homes Ground National Electrical Code ANSI NFPA No 70 and or CSA C22 1 Park Trailers ANSI 119 5 NOTE The direct high voltage spark ignition generates a...

Страница 3: ...1 2 3 4 3 Fasten plenum plate 4 E over floor cutout If a gasket and plenum plate are not used seal furnace to hard duct system mak ing sure seal is air tight continue with STEP 5 4 Position gasket 4 F...

Страница 4: ...ower or make any adjustments 3 A When set for LP and NAT is required Rotate plug and replace into valve tower NAT SHOULD NOW BE VISABLE FIG 6 B When set for NAT and LP is required Rotate plug and repl...

Страница 5: ...Blue Red Green Yellow Transformer Ignition Control Black Brown Motor 120 VAC Green 120 VAC Black 120 VAC White White Thermo Blue AC Capacitor Motor Run Thermo Blue HIGH TENSION IMPORTANT If any origin...

Страница 6: ...E F A B C D 3 2 4 G OUTSIDE RV EXTERIEUR DU VEHICULE Gas Line Conduite de gaz 1A AVANT DU VEHICULE B A 1 C 3A MUST USE MUST USE MUST USE MUST USE 6 6...

Страница 7: ...ESCRIPTION DES PI CES 2 Thermostat sp cifiez la couleur 3 Couvercle de l ouverture de branchement du conduit 4 Adaptateur de conduit 5 Lumi re PRECISEZ LE CALIBRE 6 Ventilateur d air de combustion 7 J...

Отзывы: