background image

Содержание AirDew AD-5

Страница 1: ......

Страница 2: ......

Страница 3: ...tallation precautions Operational procedures Maintenance Operation precautions Storage Cleaning top tank Cleaning bottom tank Cleaning exterior case Filter Replacement Water Filter U V Light Air Filter Water Production Chart Operational indicator Menu Set button Troubleshooting Warranty 2 2 Table of Contents 3 4 4 5 5 6 7 8 9 10 13 14 15 ...

Страница 4: ... Place unit 30 cm away from wall for proper air flow 11 DO NOT place unit near inflammables 12 DO NOT place objects on top of unit 13 If transporting unit keep up right 14 Drain water prior to moving installing unit 15 DO NOT modify or disassemble unit warranty void 16 If leak occurs unplug unit drain water call Service Centre 17 In case of electric leak unplug call Service Centre 18 Using incorre...

Страница 5: ...ld Water Storage Capacity Unit After Packing Unit After Packing Input Power Power Consumption Electrical Current Cold Water Mild Cold Normal Temperature 380 W x 520 D x 560 H mm 455 W x 580 D x 640 H mm 39 5 Kg 42 Kg 230V 50Hz 115V 60Hz 440 W 550 W 2 35 A 7 12 15 20 20 25 13 5 liters ...

Страница 6: ...n plug Power cord Easy screws Simpiy unscrew for air filter exchange 1 Hybrid power connection 2 Hybrid Connection plug 3 Hybrid power connection Kit 4 Tap water out Kit 5 Tap water in Kit Connect to the tap water through only Hybrid Kit Option AD 5 Hybrid kit Hybrid kit Hybrid kit Hybrid kit Hybrid kit Hybrid kit Hybrid kit Hybrid kit Hybrid kit Hybrid kit Hybrid kit Hybrid kit Hybrid kit Hybrid ...

Страница 7: ... Use grounded socket ONLY 4 Use socket with circuit breaker 5 DO NOT share plug with other appliances 6 DO NOT touch power socket with wet hands 7 DO NOT place heavy object on power cord Operational Procedures 1 If unit has been tilted or laid down on side do not start up for at least 30 minutes 2 Connect plug to socket 3 Push Power Button for 3 seconds to start up 4 Do a priming process See image...

Страница 8: ...revent unit from dust and store in the original box if possible Cleaning Top tank 1 Unplug power cord 2 Drain water completely 3 Pull unit until the access to the bottom is available 4 Use Phillips screwdriver to loosen 2 screws at the bottom side of front cover Image 2 1 5 Remove the front cover 6 Use Phillips screwdriver to loosen 2 screws on the rear side of top cover Image2 2 7 Remove rubber p...

Страница 9: ...h or soft cloth and mild detergent and water solution if necessary Filter replacement Water filter 1 Power off and unplug the unit 2 Remove rear cover Loosen 2 screws with Phillips screwdriver Image 3 1 3 Carefully remove filter from filter clip There may be water in hose fitting and filter Image 4 1 4 Pull and remove filter while pushing the adaptor of the fitting in opposite direction Image 4 2 ...

Страница 10: ...eset the U V replacement function by using Menu Set button see page 13 Note DO NOT look at UV ray with naked eyes Air filter 1 Separate air filter bracket by loosening 2 easy screws with hand or Phillips screwdriver Image 5 1 2 Remove air filter and replace with new air filter Image 5 2 3 After air filter exchange reset the air filter replacement function by using Menu Set button see page 13 9 9 W...

Страница 11: ...dity conditions the unit stop generating water to save energy Both temperature and humidity indicators will show as Lo signal 1 10 0 Indicator Lights 1 Temperature indicator 2 Humidity indicator 3 Generating water indicator 4 Water level indicator 5 Refresh indicator 6 U V indicator 7 Cold water temperature indicator 8 Air filter replacement indicator 9 Water filters replacement indicator 10 U F r...

Страница 12: ...Unit is in pause cycle No icon showing Water generating function has stopped See Menu Set button function Water level indicator Shows level of water in top tank If water level sensor is incorrect text will start blinking and bars light up intermittently Refresh indicator Icons rotating clockwise Unit is in re circulation cycle U V indicator Replacement of U V indicated by red text light install ne...

Страница 13: ...d filters with new ones and reset the water filters replacement indicator function by Menu Set button See page 13 Light will return to Green U F replacement indicator U F replacement Green light becomes Red Replace U F filter with new one and reset the U F replacement indicator function by Menu Set button See page 13 Light will return to Green Hybrid connection indicator Icon and text shows when h...

Страница 14: ...sh set button for 3 seconds to set reset the working mode 4 To clear the Set Reset stage push the menu button again 3 seconds or leave it for more than 5 minutes Then Set Reset function will return to previous stage Example 1 To reset Air filter replacement after exchanging air filter 1 Push menu button for 3 seconds 2 Push menu button 5 times to go to Air filter indicator 3 Push the Set button fo...

Страница 15: ...se related problems 1 Move the unit to hard flat surface 2 Has any object come in contact with the unit Cold water temperature related problems 1 Is the cold water temperature set to normal colder Set temperature to Coldest Wait at 20 minutes If water does not get cold call Service Centre 2 Has there been a large amount of water consumed When approx 1 liter of water has been taken out the cold wat...

Страница 16: ...ly or attempted repair by anyone other than a facility authorized to service the unit Warranty does not cover the unit sold As Is or With All Faults or consumables as fuses or water valves Warranty will be determined with proof of purchase unit lot number and date of issue Purchase receipt must accompany returning defective unit or parts A return authorization from your Airdew supplier must be iss...

Отзывы: