12
2.6 Setting Dome Camera Protocol and Video
If a dome camera is to be installed with the keyboard controller, select the default protocol.
Consult service personnel if a dome camera is installed with device other than a keyboard
controller.
S2
You can set video type with DIP switch.
Select video type with D1 in S2.
You can set Protocol with DIP switch D2, D3 and D4 in S2.
S2
P
ROTOCOL
D2
D3
D4
OFF
OFF
OFF
F2, F2E, Pelco-P, Pelco-D : default
OFF
OFF
ON
F2, F2E
OFF
ON
ON
Pelco-P, Pelco-D
You can set Baud Rate with DIP switch D5 and D6 in S2.
S2
B
AUD
R
ATE
D5
D6
OFF
OFF
2400 bps
OFF
ON
4800 bps
ON
OFF
9600 bps : default
ON
ON
19200 bps
Figure 5 – Video type, Protocol, Baud rate Selection Switches
2.7 Connections
• Connecting to the RS485
The dome camera can be controlled remotely by an external device or control system,
such as a control keyboard, using RS485 half-duplex serial communications signals.
• Connecting Video Output connector
Connect the video output (BNC) connector to the monitor or video input.
S2-D1
V
IDEO TYPE
OFF
NTSC
ON
PAL
Содержание 22X MINITRAX III
Страница 41: ...36 Figure 6 Dimension...
Страница 48: ...22X MINITRAX III DOME CAMERA Printed in Korea 50303340A...