ATTO Technology, Inc.
ATTO FibreBridge Software Manual
- -
36
ATTO Technology, Inc.
Element Definitions:
Device Element for Status Page
Bit
Byte
7
6
5
4
3
2
1
0
0
Common Status
1
Slot Address
2
0
0
0
0
0
0
IDENT
1
3
0
Fault
Sensed
Fault
Reqstd
0
0
0
0
0
Slot Address
: SCSI ID of this bridge (thumbwheel switch #1).
Ident:
Set to indicate the Identification control bit has been set.
Fault Sensed :
Set to indicate a fault detected by this bridge.
Fault Reqst:
Set to indicate that the RQST FAULT control bit has been set.
Power Supply Element for Status Page
Bit
Byte
7
6
5
4
3
2
1
0
0
Common Status
1
Reserved
2
Reserved
0
0
0
0
3
0
0
0
Off
0
0
0
DC Fail
Off:
Set if this power supply is off.
DC Fail:
Set if this power supply is not supplying DC Power
.
Temperature Sensor Element for Status Page
Bit
Byte
7
6
5
4
3
2
1
0
0
Common Status
1
Reserved
2
Temperature
3
Reserved
OT
Failure
OT
Warning
UT
Failure
UT
Warning
Temperature :
Degrees Celsius-20. (cannot be 0)
OT Failure/Warning:
Overtemperature status. Warning occurs at +40C. Error occurs at +50C.
UT Failure/Warning:
Under Temperature status. Warning Occurs at +5C. Error occurs at 0C.
SCSI port/transceiver Element for Status Page
Bit
Byte
7
6
5
4
3
2
1
0
0
Common Status
1
Reserved
2
Reserved
0
3
Reserved
Disable
d
Reserved
0
Xmit fail
Disabled:
Indicates that the port has been disabled.
Содержание FibreBridge 2200D
Страница 2: ...ATTO Technology Inc ATTO FibreBridge Software Manual i ATTO Technology Inc...
Страница 5: ...ATTO Technology Inc ATTO FibreBridge Software Manual iii ATTO Technology Inc...
Страница 7: ...ATTO Technology Inc ATTO FibreBridge Software Manual 2 ATTO Technology Inc...
Страница 9: ...ATTO Technology Inc ATTO FibreBridge Software Manual 4 ATTO Technology Inc...
Страница 66: ...ATTO Technology Inc ATTO FibreBridge Software Manual 3 ATTO Technology Inc...