background image

After the Brew install, install iperf:

 

brew install iperf 

To test upload speed from your client to an Isilon interface, run the following commands from the command line interface of the 
Isilon node and client shell respectively: 

isilon_node# iperf -s -w 2M -l 1M -N 

client_shell# iperf -c <node 10G IP> -w 2M -l 1M -N -t 30 

Run the command to test every combination of client network interface and Isilon node/network interface.   

To test the download speed from your client to an Isilon interface, run the following commands from the command line interface of 
the Isilon node and client shell respectively: 

isilon_node# iperf -c <client 10G IP> -w 2M -l 1M -N -t 30 

client_shell# iperf -s -w 2M -l 1M -N 

Again, ensure that this test is run from every node in the cluster.  This test provides a baseline for your potential network throughput 
without the added bottlenecks of file sharing protocol overhead and disk input/output. 

Expect at least 7-9 GB/s throughput in the results of your iperf tests.  Real-world performance is highly dependent upon your 
workflow, the Isilon node type, and your client configuration.  In Figure 4, we see the results from the Isilon 

isi statistics 

client

 command when comparing a Mac OS 10.11 client and a Windows 8.1 client. 

 

Figure 4.  Example Mac OS X and Windows 8 SMB3 performance 

In Figure 4, we see the read and write performance results of an Apple Mac Pro equipped with a ThunderLink NS2102 and a Lenovo 
D30 equipped with a FastFrame NS12.  Both client computers are equipped with 32 GB of RAM and the performance tuning options 
detailed in this document.  The Isilon OneFS v7.2.1 cluster used in this test is a 3 node X410 cluster with SSD metadata read 
acceleration and 64 GB or RAM per node.  The read tests are the result of the Mac and Windows client simultaneously playing back a 
4K DPX sequence in the BlackMagic Design Davinci Resolve 12 application.  The fnprefetch data access pattern detailed in 

EMC Isilon 

KB article 202614

 is applied recursively to the folder containing the DPX sequence.  As you can see from the results, the Windows 

8.1 client gains a significant performance advantage thanks to SMB3 Multichannel and the ability to balance traffic over dual 10GbE 
interfaces. 

The write performance results are generated from the simultaneous copy of identical folders containing a mix of large media files to 
the Isilon cluster. 

CONCLUSION 

A network featuring ATTO 10GbE connectivity offers EMC Isilon users:  

 

An easily expandable and managed storage solution that can simplify many of today's complicated workflows  

 

High-speed 10GbE interconnects for collaborative workflows that include Windows, Linux, and Mac OS X  

 

An economical, simple-to-administer 10GbE solution for real-time access to shared volumes  

 

High performance and flexibility for scenarios such as remote editing and file access  

 

The ability to connect Thunderbolt-enabled laptops and all-in-one platforms to EMC Isilon storage  

Media and entertainment workflows require high-performance storage solutions along with the ability to rapidly add new users and 
content. A workflow based on open network file-sharing protocols and the effortless scalability of EMC Isilon OneFS allows media and 
entertainment professionals to rapidly adapt to changing production requirements, ever-increasing content storage requirements, 
and increasingly complicated workflows. EMC and ATTO Technology provide flexible tools based on open protocols that easily adapt 
to your needs, while reliably supporting your tight production schedules. 

Содержание FastFrame

Страница 1: ...astFrame and ThunderLink Ethernet Adapters with EMC Isilon OneFS ABSTRACT This white paper reviews the integration requirements for the ATTO FastFrame and ThunderLink 10 GbE network adapters when desi...

Страница 2: ...change without notice The information in this publication is provided as is EMC Corporation makes no representations or warranties of any kind with respect to the information in this publication and s...

Страница 3: ...VE SUMMARY 4 Solution overview 4 GUIDELINES 4 CLIENT CONFIGURATION 4 Mac OS X Performance Tuning 5 Windows 8 2012 Performance Tuning 6 Linux Client Performance Tuning 6 NETWORK DESIGN CONSIDERATIONS 7...

Страница 4: ...ut introducing costly down time to your tight production schedules SOLUTION OVERVIEW The ATTO Technology FastFrame NS 10 GbE adapter is your gateway to high performance EMC Isilon media storage Proper...

Страница 5: ...ended transmit and receive buffer sizes for a client s network connectivity to EMC Isilon scale out NAS may be determined using the following equation Network bandwidth bytes per second x round trip d...

Страница 6: ...nk Aggregation Control Protocol LACP and each ATTO network interface should be configured independently with its own IP address SMB3 multichannel is enabled by default in OneFS version 7 1 1 and later...

Страница 7: ...only interface that is allowed to route traffic to other subnets is the gigabit Ethernet interface configured with an MTU of 1500 bytes per packet The MTU 1500 interface is also configured as the pri...

Страница 8: ...data read acceleration and 64 GB or RAM per node The read tests are the result of the Mac and Windows client simultaneously playing back a 4K DPX sequence in the BlackMagic Design Davinci Resolve 12 a...

Отзывы: