iv ATTO Technology Inc. ATTO ExpressSAS Host & RAID Adapter Installation and Operation Manual

Adapter Management

On VMware ESX/ESXi you can identify and manage ATTO adapters using the VMware vSphere Client, or the 
Service Console. On ESXi, the Service Console is referred to as Local Tech Support Mode.

vSphere Client

With VMware vSphere Client, you can identify ATTO 
adapters on a VMware ESX/ESXi system, and view 
the attached storage devices.
1

Start vSphere Client from your local workstation 
and select the host containing one or more 
ATTO adapters.

2

Click the Configuration tab, and then select 
Storage adapters under Hardware in the left 
pane.

3

A list of all storage adapters in the system is 
displayed. The Model, Identifier (SAS address) 
and Targets are shown for each adapter 
channel.

Service Console

Using the Service Console, information about each 
adapter channel can be found in the /proc/scsi 
filesystem, under /proc/scsi/<driver name>.

To view details on a specific adapter channel, run the 
following command:

# cat /proc/scsi/<driver name>/<channel>

This command displays the following information:
• Adapter 

type

• 

Driver, BIOS and Firmware versions

• Driver 

Parameters

• 

Adapter Model and Identifier (WWN or SAS 
address)

• 

Virtual Port Information

• Discovered 

Targets

• Driver 

Statistics

A sample output is shown below:

~ # cat /proc/scsi/esas2hba/6
ATTO ExpressSAS 6Gb HBA
Driver version 1.60b1
Flash version 09/27/2011
Firmware version 1.16.16
Copyright 2001-2011
http://www.attotech.com

num_targets

Maximum number of target devices. Default is 256.

old_device_reset

Use the old device reset method. Default is 0 (use 
new method).

sg_tablesize

Maximum number of entries in a scatter/gather 
table. A value of 255 means that the S/G table be 
any size. Default is 255. 

sgl_page_size

Scatter/Gather List page size in number of S/G 
entries. Default is 128.

use_tm_completions

Wait for task management commands to complete 
before returning from handler. Default is 1 
(enabled).

use_transport_layer

Attached to the SCSI transport layer. Default is 1 
(enabled).

use_multiqueue

Distributes I/O across queues based on CPU 
affinity. This may result in reduced CPU cost per 
I/O. Default is 0 (disabled).

PARAMETER

DESCRIPTION

Содержание ExpressSAS H1208 HBA

Страница 1: ...80 HBA ExpressSAS H120F HBA ExpressSAS H12F0 HBA ExpressSAS H1244 HBA ExpressSAS H1248 HBA ExpressSAS H1288 HBA ExpressSAS H644 HBA ExpressSAS H608 HBA ExpressSAS H680 HBA ExpressSAS H60F HBA ExpressS...

Страница 2: ...chnical support Monday Friday 8am 6pm EST techsupp attotech com 716 691 1999 ext 242 2015 ATTO Technology Inc All rights reserved All brand or product names are trademarks of their respective holders...

Страница 3: ...OS X Installation 13 5 Install Hardware 17 Installing the Adapter Installing CacheAssure ExpressSAS R6xx only Non Volatile NV Memory Card Installation Power Module Installation Bracket details Adapte...

Страница 4: ...ter including RAID using the ATTO ConfigTool Note Default settings are appropriate for most systems but you may change settings using the ATTO ConfigTool CAUTION CAUTION Back up your system data befor...

Страница 5: ...tion included for use with ExpressSAS 12Gb SAS HBAs with internal connections providing a cost effective option that adds performance and protection to your storage architecture To learn more about us...

Страница 6: ...ity 5 95 non condensing Power typ 12V 1 2A 3 3V 0 1A 15W Airflow 200 lf m minimum H1244 technical specifications 4 external SFF 8644 4 internal SFF 8643 SAS ports to PCIe 3 0 host interface Up to 12Gb...

Страница 7: ...8643 SAS ports to PCIe 3 0 host interface Up to 12Gb s per port performance Conforms to PCIe low profile form factor Length 6 600 Height 2 536 Operating temperature 0 55 C 32 F 131 F Operating humidit...

Страница 8: ...densing Storage temperature 40 70 C 40 F 157 F Storage humidity 5 95 non condensing Power typ 12V 0 6A 3 3V 0 2A 8W Airflow 100 lf m minimum H680 technical specifications Eight external SFF 8088 ports...

Страница 9: ...perating humidity 5 95 non condensing Storage temperature 40 70 C 40 F 157 F Storage humidity 5 95 non condensing Power typ 12V 1 6A 3 3V 0 8A 22W Airflow 100 lf m minimum H6F0 technical specification...

Страница 10: ...l SNMP R644 technical specifications Four external SFF 8088 four internal SFF 8087 ports Up to 6 Gb sec per port performance Form factor conforms to PCI low profile specification Length 6 600 Height 2...

Страница 11: ...dity 5 95 non condensing Power typ 12V 0 8A 9 6W 12V 1 22A 3 3V 06A 15 05W NVCACHE charging 12V 1 00A 3 3V 06A 12 34W NVCACHE charged Airflow 150 lf m minimum R608 technical specifications Eight inter...

Страница 12: ...et Explorer users may select Run to automatically run the downloaded self extracting executable file All other browser users select a download destination and run the self extracting executable file 9...

Страница 13: ...Open your File Browser and browse to mnt cdrom Linux Drivers 7 Click on the driver for the ExpressSAS HBAs the driver filename appears as lnx_drv_esashba _XXX tgz where is the product family and XXX...

Страница 14: ...ESXi 5 servers This allows you to include ATTO drivers as part of a boot image and install or boot ESXi 5 with that image The end result is that your server s will boot and have ATTO drivers included...

Страница 15: ...the hexadecimal number from the previous step This will launch the EFI Configuration Utility for the associated adapter 3 Use the on screen menus to configure your adapter Help is available at the bo...

Страница 16: ...Server 2012 2008 1 Start Windows text mode setup as described by your Windows documentation 2 Select Custom installation 3 The Where do you want to install Windows message appears Click Load Driver 4...

Страница 17: ...creen menus to configure your adapter Help is available at the bottom of the screen 8 When exiting the configuration utility if you changed any settings the system will restart the adapter so the new...

Страница 18: ...ettings A system NVRAM variable atto args esasraid2 atto args esashba2 for H6xx products can be used to change the behavior of the ExpressSAS driver The options are as follows e mask Specify the hexad...

Страница 19: ...ATTOExpressSASRAID2 X Y Z ATTOExpressSASHBA2 X Y Z for H6xx products where X is the PCI bus number Y is the PCI device number and Z is the PCI function number In general only errors that are output fo...

Страница 20: ...ation Please keep a reference copy of the number in a safe place Installing the Adapter WARNING ATTO ExpressSAS adapters contain components that are sensitive to electrostatic discharge ESD ESD can ca...

Страница 21: ...SAS adapter and the Found New Hardware wizard appears Proceed through the wizard with the default settings for each adapter channel Insert the ExpressSAS installation disk when prompted After adapter...

Страница 22: ...d is pre assembled to the RAID adapter If so please go directly to the Power Module Installation section If you are adding CacheAssure to a previously purchased SAS RAID adapter continue to step 3 3 G...

Страница 23: ...n its PCI Express slot 1 Remove the Power Module from its electrostatic safe packaging 2 Select an area for placement of the Power Module inside of the computer Make sure it can be mounted securely an...

Страница 24: ...21 Bracket details Exhibit 5 4 ExpressSAS H1208 HBA brackets Exhibit 5 5 ExpressSAS H1280 HBA brackets Exhibit 5 6 ExpressSAS H120F HBA brackets Exhibit 5 7 ExpressSAS H12F0 HBA brackets...

Страница 25: ...ID Adapter Installation and Operation Manual Exhibit 5 8 ExpressSAS H1288 H1248 and H1244 HBA brackets H1288 H1244 H1248 Exhibit 5 9 ExpressSAS H644 HBA brackets Exhibit 5 10 ExpressSAS H608 HBA brack...

Страница 26: ...23 Exhibit 5 12 ExpressSAS H60F HBA brackets Exhibit 5 13 ExpressSAS H6F0 HBA bracket Exhibit 5 14 ExpressSAS R644 adapter brackets Exhibit 5 15 The ExpressSAS R608 adapter brackets...

Страница 27: ...24 ATTO Technology Inc ATTO ExpressSAS Host RAID Adapter Installation and Operation Manual Exhibit 5 16 ExpressSAS R680 adapter brackets Exhibit 5 17 The ExpressSAS R60F adapter brackets...

Страница 28: ...25 Adapter board details Exhibit 5 18 ExpressSAS H1208 HBA board Exhibit 5 19 ExpressSAS H1280 HBA board Exhibit 5 20 ExpressSAS H120F HBA board...

Страница 29: ...TO Technology Inc ATTO ExpressSAS Host RAID Adapter Installation and Operation Manual Exhibit 5 21 ExpressSAS H12F0 HBA board Exhibit 5 22 ExpressSAS H1288 HBA board Exhibit 5 23 ExpressSAS H1248 HBA...

Страница 30: ...27 Exhibit 5 24 ExpressSAS H1244 HBA board Exhibit 5 25 ExpressSAS H644 HBA board Exhibit 5 26 ExpressSAS H608 HBA board...

Страница 31: ...TTO Technology Inc ATTO ExpressSAS Host RAID Adapter Installation and Operation Manual Exhibit 5 27 ExpressSAS H680 HBA board Exhibit 5 28 ExpressSAS H60F HBA board Exhibit 5 29 ExpressSAS H6F0 HBA bo...

Страница 32: ...29 Exhibit 5 30 ExpressSAS R644 adapter board Exhibit 5 31 ExpressSAS R680 adapter board Exhibit 5 32 ExpressSAS R608 adapter board...

Страница 33: ...S RAID adapter see Exhibit 6 1 This eliminates a single point of failure between the adapter and storage and may also provide a performance improvement As a third option SAS drives have two connection...

Страница 34: ...H608 and H60F These adapters have been designed to affect LED Control functionality through an SGPIO interface or an I2C interface These interfaces require different cable connections and those conne...

Страница 35: ...onnectors Exhibit 7 1 5 ESAS HBA and RAID adapter summary R608 R60F H608 H60F Overall Count Number of I2C Buses 2 2 2 4 Number of I2C Headers 2 4 2 4 Number of Mini SAS Connectors 2 4 2 4 I2C BUS I2C...

Страница 36: ...608 1 x6 Backplane J3 0 3 1 1 4 J2 4 5 1 5 6 R608 1 x8 Backplane J3 0 3 1 1 4 J2 4 7 1 5 8 R60F 1 x4 Backplanes J1 0 3 1 1 4 J2 n a n a n a J3 n a n a n a J4 n a n a n a R60F 1 x6 Backplanes J1 0 3 1...

Страница 37: ...1 1 4 J1 4 7 2 1 4 H608 1 x6 Backplane J2 0 3 1 1 4 J1 4 5 1 5 6 H608 1 x8 Backplane J2 0 3 1 1 4 J1 4 7 1 5 8 H60F 2 x4 Backplanes J1 0 3 1 1 4 J2 4 7 2 1 4 J4 n a n a n a J3 n a n a n a H60F 1 x6 B...

Страница 38: ...ce or an I2C interface These interfaces require different cable connections and those connections are specified in this chapter Using SGPIO for LED Control SGPIO with an internal mini SAS to mini SAS...

Страница 39: ...P7 0 3 1 1 4 C0 J2 P6 4 7 1 5 8 C2 R60F 2 x4 Backplanes J1 P8 0 3 1 1 4 C0 J2 P9 4 7 2 1 4 C2 J3 n a n a n a n a n a J4 n a n a n a n a n a R60F 1 x6 Backplanes J1 P8 0 3 1 1 4 C0 J2 n a 4 5 1 5 6 n a...

Страница 40: ...6 4 7 2 1 4 C0 J4 n a n a n a n a n a J3 n a n a n a n a n a H60F 1 x6 Backplanes J1 P5 0 3 1 1 4 C0 J2 n a 4 5 1 5 6 n a J4 n a n a n a n a n a J3 n a n a n a n a n a H60F 1 x4 1x6 Backplane See exam...

Страница 41: ...ample Configurations Example 1 R608 with 2 Intel x4 backplanes The backplanes are controlled by SES I2C Example 2 R608 with 2 Intel x4 backplanes The backplanes are controlled by SGPIO Example 3 R60F...

Страница 42: ...39 Example 4 H608 with 2 Intel x4 backplanes The backplanes are controlled by SES I2C Example 5 H60F with an Intel x6 backplane and an Intel x4 backplane The backplanes are controlled by SES I2C...

Страница 43: ...TO website Refer to the ATTO Utilities Installation and Operation Manual for additional information Note Logging features are only available if the ATTO ConfigTool service is installed We recommend in...

Страница 44: ...s that is used to attach low speed peripherals to a motherboard backplane or embedded system I2C Header I2C header is a connector on the adapter used to connect an I2C cable LED Light emitting diode a...

Страница 45: ...sport the SES protocol instead of SCSI SAS Fibre Channel etc SGPIO A serial GPIO protocol used to control LED indicators on a backplane Sideband Connector Connector on Mini SAS cables used to carry an...

Страница 46: ...he system log Default is 0 none atto_max_sectors Maximum number of disk sectors in a single data transfer Default is 65535 largest possible value can_queue Maximum number of commands per adapter chann...

Страница 47: ...n the following command cat proc scsi driver name channel This command displays the following information Adapter type Driver BIOS and Firmware versions Driver Parameters Adapter Model and Identifier...

Страница 48: ...Extract the contents of the tar file using tar xvzf tar file 3 Change to the extracted directory using cd vmw_app_hbacli_ date 4 Run the installer cli_install sh 5 Follow the instructions to complete...

Страница 49: ...ference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit...

Страница 50: ...TO Technology Inc limited warranty ATTO Technology Inc ATTO warrants to the original purchaser of this product Product that the Product is free from defects in material and workmanship for the term de...

Страница 51: ...THE MEDICAL FIELD OR II USE IN RUGGED APPLICATIONS ATTO IS NOT LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER ATTO HAS BEEN ADVISED OF THE POSSIBILITY OF S...

Отзывы: