ATTO Technology ATTO ExpressPCI FC 3321 Скачать руководство пользователя страница 10

5

 

ATTO Technology ExpressPCI FC 3321, 3322 and 3342 Installation and Operation Manual

2 Fibre Channel is a key technology for storage

Fibre Channel is a serial communications technology designed to transfer large amounts of data among 
a variety of hardware systems over long distances. It is a key technology for applications that require 
shared, high bandwidth access to storage.

Fibre Channel provides a logical, point-to-point, 
serial channel for the transfer of data between a 
buffer at a source device and a buffer at a 
destination device. It moves buffer contents from 
one port to another, without regard to the format 
or meaning of the data so different upper level 
protocols are able to run over Fibre Channel 
hardware.

The Fibre Channel architecture is structured as a 
hierarchical set of protocol layers. Defined within 
these layers are rules for signal interfaces, serial 
encoding and decoding, error control, frame 
format and communications protocols. 

ATTO ExpressPCI Fibre Channel host adapters 
carry SCSI protocol over Fibre Channel. 

Glossary

Some terms used in the Fibre Channel industry are defined below. More information is available 
through the ATTO Technology website 

(www.attotech.com)

, the Fibre Channel Industry Association 

(www.fibrechannel.com)

, Cern (

www.cern.ch)

, the Storage Area Networking Industry Association 

(www.snia.org)

, and the Fibre Channel Consortium (

www.iol.unh.edu/consortiums, click on FC)

Term

Definition

ANSI

American National Standards Institute

arbitrate

process of selecting one L_Port from a collection of ports which ask for use of the arbitrated loop 
at the same time

arbitrated loop

a loop topology (FC-AL) in which two or more ports are interconnected, but only two ports can 
communicate at one time; low-cost solution which may or may not use hubs and switches

auto negotiation

hardware senses and automatically responds depending on configuration

BER

Bit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent

bit

Smallest unit of data a computer can process: a single binary digit with a value of either 0 or 1

bus

a collection of unbroken signal lines used to transmit information from one part of a computer 
system to another; taps on the lines connect devices to the bus

Byte

an ordered set of 8 bits

channel

a point-to-point link which transports data from one point to another

CPU

Central Processing Unit: the portion of the computer that actually performs computations

CRC

Cyclic Redundancy Check: an error-correcting code which calculates a numeric value for received 
and transmitted data; if no error has occurred during transmission, the CRC for both received and 
transmitted data should be the same

destination 
address

a value in the frame header of each frame which identifies the port in the node where the frame is 
being sent

device driver

a program that allows a microprocessor to direct the operation of a peripheral device

DMA

Direct Memory Access: a way to move data from a storage device directly to RAM without using 
the CPU’s resources

DMA bus master

Allows a peripheral to control the flow of data to and from system memory by block as opposed to 
allowing the processor to control the data by bytes (PIO or programmed I/O)

Содержание ATTO ExpressPCI FC 3321

Страница 1: ...r SW optical LC SFP interface ATTO ExpressPCI FC 3342 Quad channel 2 Gigabit FC to PCI X Host Adapter SW optical LC SFP interface 2003 ATTO Technology Inc All rights reserved All brand or product name...

Страница 2: ......

Страница 3: ...Interface Advanced FC Features Advanced SCSI FCP Support Exclusive Advanced Data Streaming ADS Technology Accelerated PCI Bus Management Environmental Physical Specifications 2 Fibre Channel is a key...

Страница 4: ...Appendix A Standards and compliances i Appendix B Fibre Channel accessories ii Appendix C SCSI host adapter selection guide iii Appendix D Contact ATTO Technology Inc iv...

Страница 5: ......

Страница 6: ...annel topologies Point to point Arbitrated loop Switched fabric FL port F port Strict adherence to ANSI specifications FC PH FC AL2 FC FCP FC PLDA FC FLA FCA IP iETF iPFC FC Tape Supports Class 2 and...

Страница 7: ...CA IP iETF iPFC FC Tape Supports Class 2 and Class 3 transfers LEDs indicate link activity on line and fault status for each channel Flash ROM for easy field upgrades Advanced FC Features Support for...

Страница 8: ...SI specifications FC PH FC AL2 FC FCP FC PLDA FC FLA FCA IP iETF iPFC FC Tape Supports Class 2 and Class 3 transfers LEDs indicate link activity on line and fault status for each channel Flash ROM for...

Страница 9: ...nnel 400MB secper channel 400 MB sec 400 MB sec Class transfers 2 3 2 3 2 3 2 3 2 3 Full duplex 7 7 7 7 7 66 33 MHz PCI compatible 66 MHz only 7 7 7 7 133 MHz PCI X compatible 7 7 64 and 32 bit PCI co...

Страница 10: ...Port from a collection of ports which ask for use of the arbitrated loop at the same time arbitrated loop a loop topology FC AL in which two or more ports are interconnected but only two ports can com...

Страница 11: ...iguration originator an initiating device a component which originates a command parity checking A method which verifies the accuracy of data transmitted over the SCSI bus by adding one bit in the tra...

Страница 12: ...ss is clearly marked on the back of the board for easy identification Please keep a reference copy of the number in a safe place or write in the space provided below ExpressPCI FC host adapter WWNs ar...

Страница 13: ...should use 50 micron multi mode optical cables Cable length should be no more than 500 meters ExpressPCI FC 3342 The ATTO ExpressPCI FC 3342 has four pluggable SFP LC optical connectors and uses a sh...

Страница 14: ...Installation and Operation Manual Exhibit 3 3 ExpressPCI FC 3322 bracket and board Exhibit 3 4 Express PCI FC 3342 bracket and board FC Controller ExpressPCI FC 3322 bracket and board ExpressPCI FC 3...

Страница 15: ...excellent performance for a wide range of applications some specialized applications may benefit from modification of the adapter settings to tune the adapter for a specific performance range The Expr...

Страница 16: ...r for my device option 4 Insert the ATTO ExpressPro Tools CD 5 In next window be sure the CD ROM is selected as the source for the driver 6 Once the system finds the driver click the Next button 7 Cli...

Страница 17: ...e files to your desktop and install the Configuration Tool on your system 4 Launch the Configuration Tool 5 In the Device window select the adapter that needs to be updated 6 In the Flash window click...

Страница 18: ...lled Follow the procedure in Chapter 4 All of the external devices connected to the host adapter should be identified If they do not appear in the Device Manager the external devices or connection may...

Страница 19: ...in the loop should be identified If they do not appear in the Device List the external devices or connection are not working properly If the card has been recently re flashed with new firmware the new...

Страница 20: ...o which the receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian standards This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num r...

Страница 21: ...SCSI products are also available from ATTO Technology Please contact your ATTO sales representative for product descriptions and part number information Fibre Channel solutions FC Rack System Modular...

Страница 22: ...lable and include an ExpressPCI SCSI host adapter ExpressRAID software and appropriate cable s Add KIT suffix to host adapter product code i e EPCI UL3D KIT Specific features Single Channel ExpressPCI...

Страница 23: ...ern Standard Time 8 00 a m to 8 00 p m or by e mail and web site 24 hours a day ATTO Technology Inc 155 CrossPoint Parkway Amherst New York 14068 716 691 1999 voice 716 691 9353 fax http www attotech...

Отзывы: