background image

ƒ

  The firmware and driver may not be at compatible revision levels. The drivers are 

updated more frequently than the firmware, therefore the revision levels are 
seldom the same.  There may be an occasion where the latest driver also 
requires a firmware update.

  

Verify from the web site that the latest firmware and 

driver version are being used.  The firmware version can be viewed when the 
host adapter is detected during the computer’s BIOS scan.  The driver version 
can be verified from within the Device Manager.  

 

 
 
 

Æ

 The Celerity host adapter is detected by the operating system, it detects some of 

the connected devices on some or all Fibre ports, but does not detect all of the 
connected devices.   

 

ƒ

  Verify the Fibre devices are all powered on. 

ƒ

  Check cable integrity. Check the cables for solid connections. Make sure they 

snap into place. Inspect cable for kinks or cuts. 

ƒ

  Verify the SFP is not damaged and rated for the Data Rate trying to be achieved. 

Also, try reseating the SFP. If this does not work, try replacing the SFP with a 
new one.

 

ƒ

  Try connecting one device at a time, adding devices until the problem occurs.  

This will help pinpoint the device or cable causing the problem.

 

ƒ

  Watch the LED indicators on the Fibre card. They should show when you have a 

proper link and the connection speed you have negotiated with the device after 
startup. Drive lights should also flash at startup as the Fibre port is scanned.  
This may give a clue as to the root cause of the issue.  

 
 
 

Æ

 Errors are reported while trying to flash new firmware onto the Celerity host 

adapter.  

ƒ

  The ATTO Configuration Tool performs validations on the structure of the file.  If 

it does not pass these validations, the file is rejected.  The image file may be 
corrupted.  Try downloading the image file from the support section of the 
website again. If you continue to have problems, contact our Technical Support 
Department. 

 
 
 
 
 

Æ

 The Celerity host adapter fails its Power On Self Test/Post.   

ƒ

  The BIOS driver will perform several checks to verify that the host adapter is 

functioning.  If the BIOS driver determines that the adapter has non-functioning 
hardware it will not complete the initialization of the OS driver.  If the BIOS driver 
determines that the FW on the adapter is not functioning, then it will complete the 
initialization in degraded mode.  Under Windows, degraded mode will not 
perform I/O but it will allow the end user to flash the adapter with working FW.  
The POST failure will be recorded in the Windows Event Log.  Try to re-flash the 

Page 5 of 9 

Atto Technology, Inc. 

April 9,2007 

Содержание ATTO Celerity FC-42XS

Страница 1: ...the computer If this resolves the issue investigate the Fibre cables SFP s or Fibre target devices as described in the section below If the computer still does not boot try installing the host adapte...

Страница 2: ...nd reboot the system If the system still freezes Remove any non vital PCI cards from the system to determine if there is a PCI port conflict Remove the Celerity host adapter and test it in a different...

Страница 3: ...OS may have been set to disabled factory default BIOS enabled Set it back to Enabled if you need to boot from an external device connected to the host adapter or Scan Only Verify the Fibre devices are...

Страница 4: ...g the SFP If this does not work try replacing the SFP with a new one If multiple Fibre Devices are being attached switch multiple Drive Arrays try connecting one device at a time adding devices until...

Страница 5: ...em Watch the LED indicators on the Fibre card They should show when you have a proper link and the connection speed you have negotiated with the device after startup Drive lights should also flash at...

Страница 6: ...ions cause a warning or error message to be posted in the Status area of the configuration utility These messages will be shown in red o An error occurred loading NVRAM data The first time a host adap...

Страница 7: ...bled To enable the advanced event logging features of the ATTO Celerity FC Host Adapter in a Windows environment please do the following Click Start and Run Type regedit to start the registry editor F...

Страница 8: ...3 OS Patch Level 4 PCI slot and type 5 ATTO driver version 6 ATTO firmware revision 7 List all of the devices attached to the ATTO HBA Include the manufacturer and model number for each device 8 Did...

Страница 9: ...icable is the error Does the error occur sporadically randomly or can it be reproduced each and every time 13 If the system was working previously what changed about the configuration Page 9 of 9 Atto...

Отзывы: