28
English
RAIS/
attika
- User manual for VIVA L Gas
Horizontal Wall Terminal type C11
Dimension of outflow pipe:
Viva L
Ø100 / Ø150 Outlet connection piece on the stove
Ø100 / Ø150 Can be used for the entire chimney, or,
Ø130 / Ø200 Adapter can be used so that you can use
Ø130 / Ø200 after the adapter�
Outlet terminal
Ø130 / Ø200 Art� no� USDHC 130
Ø100 / Ø150
Art� no� USDHC 100
Maximum length of outflow pipe to external wall (H)
= 4 X Vertical outlet pipe length (V) -1� for Ø130 / Ø200 pipe�
= 2 X Vertical outlet pipe length (V) � for Ø100/Ø150 pipe�
Maximum permissible length (H) = 15M�
Maximum vertical height of outlet pipe for Viva L = 0�5m
vertical length of out-
let pipe
(V) in metres
Maximum length of
Horizontal outlet pipe
(H) in metres Ø130/
Ø200
Maximum length of
Horizontal outlet pipe
(H) in metres Ø130/
Ø200
0�5
1
1
1
3
2
1�5
5
3
2
7
4
2�5
9
5
3
11
6
3�5
13
7
4
15
8
4�5
15
9
5
15
10
5�5
15
11
6�5
15
13
7
15
14
7�5 <
15
15
Flue gas Limiter to Ø100/Ø150
Vertical height < 1m
No limiter
Vertical height 1-2m
Ø62mm limiter
Vertical height > 2m
Ø76mm limiter
Содержание Viva 100 L G
Страница 32: ...32 English RAIS attika User manual for VIVA L Gas ceramic Logs Log 1 Log 2 Log 3 Log 4 Log 5 Log 6 Log A Log B...
Страница 34: ...34 English RAIS attika User manual for VIVA L Gas Log 3 Log 4 Log 5...
Страница 35: ...35 Sample photos English RAIS attika User manual for VIVA L Gas Log 6 Log A Log B...
Страница 40: ...40 English RAIS attika User manual for VIVA L Gas...
Страница 75: ...1 2 3 4 5 6 7 8 Viva 100 L Gas Viva 120 L Gas Viva 160 L Gas...
Страница 76: ...78 1 2 3 4 5 6 7 8 9 10 11 12 14 13 15 Viva 100 L G Gas Viva 120 L G Gas Viva 160 L G Gas...