Attero Tech unAIO2X2+ Скачать руководство пользователя страница 2

 

 

 

User Manual 

 Attero Tech LLC 2018 

Page 1 

614-00040  Rev 01 

 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

The symbols below are internationally accepted symbols that warn of potential hazards with electrical products. 

 
This  symbol,  wherever  it  appears,  alerts  you  to  the  presence  of  un-insulated  dangerous  voltage  inside  the 

enclosure -- voltage that may be sufficient to constitute a risk of shock. 
 

This  symbol,  wherever  it  appears,  alerts  you  to  important  operating  and  maintenance  instructions  in  the 
accompanying literature. Please read the manual. 

 

1.

 

Read these instructions. 

2.

 

Keep these instructions. 

3.

 

Heed all warnings. 

4.

 

Follow all instructions. 

5.

 

Do not use this apparatus near water. 

6.

 

Clean only with a dry cloth. 

7.

 

Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 

8.

 

Do  not  install  near any  heat  sources  such as radiators,  heat  registers,  stoves,  or other apparatus  (including 
amplifiers) that produce heat. 

9.

 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with 
one wider than the other. A grounding type plug has two blades and third grounding prong. The wider blade or 

the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician 
for replacement of the obsolete outlet. 

10.

 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the 

point where they exit from the apparatus. 

11.

 

Only use attachments/accessories specified by Attero Tech 

12.

 

Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. 

13.

 

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 

14.

 

Unplug this apparatus during lightning storms or when unused for long periods of time. 

15.

 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in 

any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the 
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 

16.

 

This apparatus shall be connected to a mains socket outlet with a protective earthing connection. 

17.

 

When permanently connected, on all-pole mains switch with a contact separation of at least 3mm in each pole 

shall be incorporated in the electrical installation of the building. 

18.

 

If rack mounting, provide adequate ventilation. Equipment may be located above or below this apparatus but 

some equipment (like large power amplifiers) may cause an unacceptable amount of hum or may generate too 
much heat and degrade the performance of this apparatus, 

 

  TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. 

Содержание unAIO2X2+

Страница 1: ...User Manual Attero Tech LLC 1315 Directors Row Suite 107 Ft Wayne IN 46808 Phone 260 496 9668 Fax 260 496 9879 www atterotech com 614 00040 unAIO2X2 2x2 AES67 Interface User Manual Date 03 21 18 Revis...

Страница 2: ...outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories spe...

Страница 3: ...warranty as outlined above NEITHER ATTERO TECH LLC NOR ANYONE INVOLVED IN THE PRODUCTION OR DELIVERY OF THE EQUIPMENT SHALL BE LIABLE FOR ANY INDIRECT SPECIAL PUNITIVE CONSEQUENTIAL OR INCIDENTAL DAM...

Страница 4: ...Connections 1 2 3 1 Balanced Output to a Balanced Input 1 2 3 2 Balanced Output to an Unbalanced Input 1 2 3 3 Unbalanced Output to an Balanced Input 2 3 Device Configuration 3 3 1 IP Address Setup 3...

Страница 5: ...option is particularly useful if the unAIO2X2 is mounted in a remote location where access to a mains outlet is limited or indeed nonexistent The unit comes in a small form factor with integrated mou...

Страница 6: ...art only 4 Ethernet interface connector and indicators 5 2 x Balanced line audio inputs 6 2 x Balanced line audio outputs Note The unAIO2X2 has a label on one of the mounting flanges that shows the MA...

Страница 7: ...onnected requires in order to find how to connect it correctly see Hardware Connections section 2 3 for further details When powering using PoE o Attach the network port to a spare PoE enabled port on...

Страница 8: ...three LED s are SYS SYNC and ERROR and the color of each LED has different meanings The tables below show the combination and what each combination means Color Description Red System booting Orange E...

Страница 9: ...hieve the best audio performance throughout the system 2 3 1 Balanced Output to a Balanced Input 3 Wire Cable Pin 1 Pin 2 GND Balanced Output Terminal Block Plug Pin 3 1 2 3 XLR M 3 Wire Cable Sleeve...

Страница 10: ...age 2 614 00040 Rev 01 2 3 3 Unbalanced Output to an Balanced Input Balanced Input Terminal Block Plug 2 Wire Cable Sleeve Tip TS Plug GND Balanced Input Terminal Block Plug 2 Wire Cable Sleeve Tip RC...

Страница 11: ...gure IP addresses will not allow a unAIO2X2 device to correctly authenticate in the unIFY Control Panel software The input and output channels won t be visible and routing of audio to and from the unA...

Страница 12: ...stream data will be removed The network settings will also be reset so the device will return to retrieving an IP address dynamically The power up defaults for the audio settings are also cleared For...

Страница 13: ...22 Class A and EN55024 Class A and RoHS requirements The unit shall be the Attero Tech unAIO2x2 I O Interface 4 1 Device Specifications Audio Network Physical Level Standard Ethernet Connector Single...

Страница 14: ...ttero Tech LLC 2018 Page A 1 614 00040 Rev 01 APPENDIX A Reference Documents The following table lists the relevant reference documents Document Title Location unIFY 3rd Party Software API Registered...

Страница 15: ...Released Revision History Revision Date Author Description of change 00_a 08 08 17 CNL Initial Draft 00_b 11 1 2017 AJB Corrected grammar errors 00_c 11 13 17 CNL Changed Front back images to that of...

Отзывы: