background image

Warning

Warning    Misuse of this product may lead to serious injury or death to the user.
Caution     Misuse of this product may lead to serious injury to the user or material damage to 

                   the object involved.

             

●  To ensure the normal operation of this product’s ESD function, only three-core power cord 

     shall be used as the host connecting line.

●  Do not play or do other similar dangerous actions when using this equipment, because it can 

     easily lead to injury to others or yourself.

●  Do not use this product for purposes other than de-soldering.

●  Do not modify this product and its accessories, otherwise the original warranty will be invalidated 

     or damage may occur to the product.

●  When plugging and unplugging the power cord and handle plug, please hold the plug body and 

      do not pull the cord.

●  Do not hit the product or its accessories too hard during the operation; otherwise damage may 

     occur to the product.

Caution

●  Keep this product away from flammable materials.

●  Keep the product out of children's reach.

●  Do not use this product if you are inexperienced or have no sufficient necessary knowledge 

      without the guidance of related personnel.

●  Do not use this product under wet environment or with wet hands to avoid electric shock.

●  Do not modify this product or its accessories without authorization.

●  Please turn off the power when replacing parts and iron tips, and do not resume the use until 

      the equipment is completely cooled down.

●  Please use the accessories from the original factory when replacing the product parts.

●  Make sure to turn off the power switch when the equipment is temporarily stopped or out of use.

2

Copyright information

Description of common symbols

Essential knowledge for users

Safety precautions

Disclaimer

The design of this product (including internal software) and its accessories is under the protection of 

relevant state laws. Any infringement upon the relevant rights of our company will be subject to legal 

sanctions. Users shall consciously abide by the relevant state laws when using this product.

Thank you for using our products. Before using the product, please read this manual carefully and pay 

attention to the relevant warnings and cautions mentioned in this manual.

Users are required to have basic knowledge of common sense and electrical operations before using 

the product.Minors shall use the product under the guidance of a professional or guardian.

[Caution]: To avoid damaging the equipment and keep the safety of the operational environment, 

please read this manual carefully before use and keep it well so that you may read it at any time 

when necessary.

To avoid electric shock or injury to the human body or fire hazard, the following basic rules must be 

observed when using the equipment. In order to ensure personal safety, only parts and accessories 

approved or recommended by the original factory can be used, otherwise, serious consequences may 

occur!

When using this product, the spray nozzle of hot air gun, with the temperature up to 100-480℃, may 

cause burns to the user or cause a fire due to improper application. So Users shall strictly observe 

the following rules:

We will take no responsibility for any personal injury or property damage caused by reasons other than 

the product quality problem, which may include force majeure (natural disasters, etc.) or personal 

behavior during the operation of this product.

This manual is organized, compiled and released by SHENZHEN ATTEN TECHNOLOGY CO., LTD. 

according to the latest product features. We will not be responsible for further notice of the subsequent 

improvement of the product and this Manual. 

Содержание GT-8102

Страница 1: ...GT 8102 Hot Air Desoldering Station User Manual GT compatible...

Страница 2: ......

Страница 3: ...Host system setup parameters Total items of function setup menu Diagram of keypad functions in curve mode Curve working interface Product warranty After sales contact Appendix Product warranty card 2...

Страница 4: ...ty precautions Disclaimer The design of this product including internal software and its accessories is under the protection of relevant state laws Any infringement upon the relevant rights of our com...

Страница 5: ...s 1 Set 1 Pcs 1 Set 2 2 Pcs Vacuum pen Hot air gun handle Conformity certificate Double male connector Tool box Suction nozzle Power line Double male connector Conformity certificate Handle holder Spr...

Страница 6: ...switch reuse key System setup menu switching key 7 Rapid temperature key 3 System setup menu switching key Power plug connected to rated AC power Power master switch RS232 communication interface Han...

Страница 7: ...g When replacing the hot air handle be sure to turn off the power switch of host and unplug the power plug to avoid electric shock 5 6 5 Connect to the signal line of dormancy switch With dormancy fun...

Страница 8: ...AC 1000W Max 100 480 212 896 Support Chinese English interface Chinese interface by default 25 99 10 900S by default 10 100 Three groups of rapid temperature 50 90 Five dynamic power bars Available En...

Страница 9: ...mperature Display of actual temperature Heating power strength display 7 50 50 50 50 c 300 o 200 300 400 GT 8102 normal working interface Standby 1 6 7 4 3 5 2 8 9 Aften connected with charger turn on...

Страница 10: ...to switch the air volume setup and temperature setup If selecting the icon it means setting the air volume If selecting the icon it means setting the temperature When setting the air volume press and...

Страница 11: ...ec the vacuum pen function can be enabled and the icon will be displayed 2 Then long press the key 2 again and the vacuum pen function will be disabled When the vacuum pen function is enabled the vacu...

Страница 12: ...e Keypad Tone The switch to turn on and off the key operation tone LCM Contrast Contrast ratio adjustment displayed on the screen 10 If the configuration page is under the protection of password the l...

Страница 13: ...nguages Unit Password Mode Net Address Factory Default Exit System set Nor 1 Host system setup parameters System set Unit System set Password 11 Mode Used to define the Host communication not availabl...

Страница 14: ...word and display the prompt locked by the system Press Enter to return to the password setup Enter the correct password the system is unlocked and the password is cancelled Enter the incorrect passwor...

Страница 15: ...m set ON 44 Nor Mode 1 Net Address Factory Default LCM Contrast System set 44 Nor Mode 1 Net Address Factory Default Exit System set Net Address Password Keypad Tone LCM Contrast ON Nor 4 1 4 Mode Net...

Страница 16: ...l Shortcut Air 1 Set air volume1for user s quick call Shortcut Tmep 2 Set temperature 2 for user s quick call Shortcut Air 2 Set air volume2 for user s quick call Shortcut Tmep 3 Set temperature 3 for...

Страница 17: ...t can be corrected through parameter modification as follows 1 Set the handle temperature to be corrected at a suitable value e g 350 662 2 After the temperature remains stable test the actual tempera...

Страница 18: ...should be no less than or equal to the minimum temperature The factory default is 480 896 The minimum temperature that can be set by the user in the main working interface The set minimum temperature...

Страница 19: ...ss to run the curve long press for curve setup Curve number plus 1 2 3 4 5 6 Shortcut key of curve 2 long press to run the vacuum pen function Shortcut key of curve 3 Diagram of keypad functions in cu...

Страница 20: ...Setup Edit Profile UI Mode Profile Setup UI Mode 18 1 UI Mode Current working mode is curve mode Edit Profile Change the set curve parameters Copy Profile Copy the existing curve Delete Profile Delet...

Страница 21: ...l step during the operation of hot air handle The total time of all steps is 600S at most Temperature Operating temperature during the operation of hot air handle 100 480 closed when the temperature i...

Страница 22: ...te curve Delete Profile Profile Setup Delete Profile 20 C Are you sure No Yes Source 1 Dest 7 Copy Profile Profile 1 copied to 7 Finish copying the curve Copy Profile Hold MENU key to enter the Copy c...

Страница 23: ...Hold MENU key to exit the curve setup and enter the running curve Press or on the panel to select the curve to be deleted Exit Profile Setup Exit 21 C Selet Profile 7 Are you sure Finish deleting the...

Страница 24: ...oblem occurs you can try to adopt the following measures to solve it If the problem still cannot be solved please return the equipment to the original factory for inspection 1 Check if the socket swit...

Страница 25: ...period we provide life long maintenance services For those product damaged due to users improper application and unauthorized changes to the product parts our company only provides limited warranty se...

Страница 26: ...9 Material name Serial No Material name Serial No 10 11 12 13 Transformer Rubber air pipe 14 Bottom shell Brushless fan 5 1 Power board PCB Vacuum pump cover Vacuum pump Vacuum pump holder Sponge 6 1...

Страница 27: ...nd within the guarantee period we will response for the maintenance free of charge on presentation of this card and the receipt We will repair and return the repaired equipment to the customer within...

Страница 28: ...CO LTD Soldering iron Soldering station Hot air rework station Multi function maintenance system Regulated DC power supply Switching DC power supply Programmable power supply All Copyright Reserved M...

Отзывы: