background image

MFR Add: Building A29, Tanglang Industrial Zone, Xili, 

Nanshan, Shenzhen, 518055, P. R. China

Tel: 0755-8602 1373   8602 1372   

 Fax: 86-755-8602 1337

http: //www.atten.com.cn    

E-mail: [email protected]

SHENZHEN ATTEN ELECTRONICS CO., LTD.

If you have any advice or requirements, please feedback or call 0755-86021373.

Thanks for using our products, please read this manual thoroughly before operation. 

ATTEN INSTRUMENTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RF Microwave Instruments   

 

Therefore Microwave Components   

 

Spectrum Analyzers

 

Regulated DC Power Supply  

 

Regulated AC Power Supply   

 

Switching DC Power Supply

 

Inverter DC Power Supply

 

Portable Power     

 

Oscilloscope/ Signal Generator

 

Attenuator/ Amplifier   

 

850 Rework Station       

 

936 Constant Temp Soldering Station   

 

Electronic Instruments

 

Electronic Tools

FRANCHISER

SHENZHEN ATTEN ELECTRONICS CO., LTD.

Users Manual

Содержание AT6010

Страница 1: ...hanks for using our products please read this manual thoroughly before operation ATTEN INSTRUMENTS RF Microwave Instruments Therefore Microwave Components Spectrum Analyzers Regulated DC Power Supply...

Страница 2: ...mine the fault point Electromagnetic Compatible EMC Testing measure the function of harmful electromagnetic wave to be transmitted by various electronic equipments In addition it can output AM FM demo...

Страница 3: ...ly connected to an AT6010 AT6011 series spectrum analyzer Signal feed via a 1 5m BNC cable When used in connection with a spectrum analyzer or measuring receiver the probes cable used to locate and qu...

Страница 4: ...m analyzers best partner Since the phone s receiving signals transmit by base station are instability normally between 70dBm to 90dBm and maybe weaker in some place or even no signal In order to make...

Страница 5: ...ny unintended operation The protection is likely to be impaired if for example the instrument shows visible damage fails to perform the intended measurements has been subjected to prolonged storage un...

Страница 6: ...F is the first intermediate frequency which passes through a waveband filter tuned to a center frequency of 1350MHz It then enters an amplifier and this is followed by two additional mixing stages osc...

Страница 7: ...center frequency is set to 500MHz If the baseline tends to move upwards when the attenuation is decreased it may indicate spectral lines outside the maximum displayable frequency range i e 1200MHz wi...

Страница 8: ...is more sensitive to low level distortion than a scope Sine waves may look in the time domain but in the frequency domain harmonic distortion can be seen The sensitivity and wide dynamic range of the...

Страница 9: ...signal means distinguishing it from its nearest neighbors The resolution of a spectrum analyzer is determined by its IF bandwidth The IF bandwidth is usually the 3dB bandwidth of the IF filter The rat...

Страница 10: ...ortion free range is called the spurious free dynamic range of the analyzer The display dynamic range is defined as the ratio of the largest signal to the smallest signal that can be displayed simulta...

Страница 11: ...ents are well installation reliable fasten and flexible operability Warm up for one hour to inspect the performances 2 Inspection of Y POS Adjust Y POS knob occurs hand feeling by obvious locating poi...