background image

Operating Instructions

1. Precautions before use

AC power input: AC power input shall be within the range of rated voltage ±10% 
50/60hz.

Warning: the protective conductor of the power line must be earthed to 
avoid electric shock.

Instrument installation: Avoid using this power supply in the environment above 
40

. Reserve enough space for heat emission holes on the rear panel to 

dissipate heat.

Notice: To avoid damage to the instrument, do not operate it in the 
environment above 40

.

2. Output voltage regulation

1.  Turn on the power switch to make the product work normally.
2.  Adjust the knob to the right to increase the output voltage value.
3.  Adjust the knob to the left to reduce the output voltage value.
4.  Press the adjusting knob forward to change fine/coarse adjustment status.
5.  Conduct step adjustment at 0.01V in the in the fine adjustment state and 0.1V 
    in the fine adjustment state.

3. Output current regulation

1.  When the current switch is switched to the position 0.5A, the host can provide 

    the current output capacity of 0.5A.

2.  When the actual output current exceeds 0.6A at the position 0.5A, the power 

    supply will automatically conduct overrange protection. At this time, the power 

    supply will temporarily shut off the output for about 2S and make a buzzing 

    alarm to prompt the user to switch positions.

3.  When the current switch is switched to the position 3A, the host can provide 

    the current output capacity of 3A.

4.  When the actual output current exceeds 3.2A at the position 3A, the power 

    supply will automatically conduct overrun protection. At this time, the power 

    supply will temporarily shut off the output for about 2S and make a buzzing 

    alarm to prompt the user to remove the load.

Product Panel Diagram

① 

Voltage display

Main current 
display

Adjusting knob
Fine tuning
/locking key

Front Panel Diagram

APS15-3A

15V

5V

3A

0.5A

FINE

-

+

POWER

VOLTAGE

5

 

Output port

9

Power switch

6

USB output

4

Current

3

 

Voltage

8

7

Pointer header 
zero calibration

2

6

5

7

Recovery time: ≤ 120 μs (50% load variation, minimum load of 0.5A).
Ripple and noise: ≤ 0.5mVrms (5Hz~1MHz) (rated current ≤ 1A).
Ripple and noise: ≤ 1.0mVrmss (5Hz~1MHz) (rated current >1A).
Temperature coefficient: ≤ 300ppm/

Read-back display:

The company will provide a warranty period of two years for the user since the date of 
sale. The company will provide free maintenance service for the faults caused by quality 
problems in the normal use within the warranty period.

The company will provide the product beyond the warranty period with lifelong 
maintenance service.

The company will only provide the limited warranty service for the damage caused by the 
user's improper use or arbitrary change to product components.

In case of product failure, please send the product to the designated maintenance point 
for maintenance. Unauthorized maintenance points and personnel shall not maintain the 
product.

Product Warranty

After-sales Service

After-sales service hotline: (+86)0755-23408704
For more contact information, visit the official website www.atten.com.cn.

After-sales Information

Display: double 3-bit LCD with blue background and white words (main 
              voltage and USB current display)
Accuracy: LCD header: ±(0.5% r 2 bits); 
                 current pointer header: CLASS-2.5

USB interface parameters:

Voltage: fixed 5V output (±5% accuracy)
Current: maximum 2.1A (overcurrent protection, cut-off output)

4. Voltage range setting

1.  When the voltage is switched to the position 5V, the host provides the 
    maximum limited voltage output of about 5.1V.
2.  When the voltage is switched to the position 5V, the host provides the 
    maximum limited voltage output of about 15.5V.

5. Parameter locking operation

1.  Under normal working conditions, long press the knob for about 3S to lock 
    the voltage output parameters.
2.  In the locking state, the locking icon will be displayed on the LCD. At this 
    time, the adjusting knob is inactive.
3.  Long press the knob again for about 3S to release the parameter locking. 
    At this time, the voltage can be adjusted normally.

6. Sound ON/OFF

1.  Turn on the power switch to turn on/off the sound function while pressing the 
   knob.
2.  When the sound function is turned off, the alarm sound will also be heard if 
    the current exceeds the range.

5V/2.1A

(5V/2.1A)

Отзывы: