6.3.1 SET MANUAL
It
corresponds to the room heating temperature
set during the Manual program (it can be modified
also from Room Home turning the knob). Range
10.0÷25.0°C, by increments of 1°C (default 20.0°C).
6.3.3 SET COMFORT
It
corresponds to the room heating temperature set
during the Comfort periods of Automatic program.
Range 10.0÷25.0°C, by increments of di 1°C (default
20.0°C).
6.3.4 SET ECONOMY
It
corresponds to the room heating temperature
set during the Economy periods in the Automatic
program. Range 10.0÷25.0°C, by increments of di
1°C (default 16.0°C).
6.3.5 TIME SCHEDULING
It
includes the time scheduling window through
which it is possible to define a weekly time schedule
for Heating Mode (it can be enabled choosing the
Automatic program at Mode page). See what written
for Hot Water with the difference that the Comfort
and Economy temperatures have to be followed.
6.3.6 NO-FROST FUNCTION
Entering the page, it is possible to enable/disable
this function and set up the working temperature.
The antifreeze temperature set is the temperature
used by the device to make a heating request to the
minimum delivery set. This request is maintained
until the room temperature exceeds the set itself.
Range 0.5÷10.0°C (default 5.0°C).
6.3.7 WATER FILLING
Entering this function, the pressure of the system is
displayed and, if it is low, it is possible to load the
system pressing the knob when the item
Manual
filling
is selected (if the UC can stand the function).
Since it is a delicate procedure, after pressing the
knob, one more confirmation is required.
6.3.8 PARAMETER SETTINGS
The
Submenu offers the access to
restricted
settings, as a consequence, before their opening,
the page
Confirmation Request
is displayed. Once
confirmed the enter procedure, it is possible to
modify the following parameters:
•
ROOM SENSOR ENABLE
If it is set (YES), the delivery temperature is
fixed considering both the room temperature
measured by the device inner probe and the
Room Set.
•
ROOM SENSOR MODULATION
If it is set (YES), the delivery temperature