![ATTACK AWP 25 Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/attack/awp-25/awp-25_instructions-for-use-manual_3005323090.webp)
89
Service parameters, page 5
Pic. 98
Number of suction retries –
the number of suction repeats in failed attempts
Turbine max runtime -
determines how long a vacuum fan will suck in pellets without a break
Turbine rest time-
determines how long the turbine will have a pause in suction after which it
will be switched on again
Power regulator worktime –
control time PID control model (set from factory)
Power regulator P – Part
– proportional part of PID control model (set from factory)
Power regulator D – Part -
differential part of PID control model (set from factory)
Power regulator I – Part
– integral part of PID control model (set factory setting)
Buffer uninstalled -
after activation of this function the boiler will be controlled according to
the temperature of the accumulation tank
Содержание AWP 25
Страница 1: ...www attack sk ATTACK WOOD PELLET Instruction for use EN EN 06 2019...
Страница 2: ......
Страница 30: ...29 Coming out from Test menu 2 Pic 15 Coming out from Test menu 3 Pic 16...
Страница 51: ...50 Message Missing Fuel Pic 49 Burn Out mode Pic 50...
Страница 72: ...71 New Software Update Pic 82...
Страница 86: ...85 Service parameters page 1 Pic 94...
Страница 98: ......
Страница 99: ......