28
Troubleshooting
Error Messages
Error message
Solution
Black user screen
Remove battery cover and check
•
Main switch is activated
•
Reset the thermo fuse
•
Battery cable logs and connections
•
Measure battery voltage
Remove handlebar cover and check
•
The electric fuse
User screen turns off immediately after start-up attempt
Reset safety switch on the handlebar
No preheat after 15 seconds
Terminal will show
•
To low battery voltage
•
To low fuel level
•
Wait 2 minutes and try again
Low battery level. symbol flashes red.
Recharge the battery with the battery charger.
Low fuel level. The fuel level symbol flashes red.
Fill up with fuel. Wait 2 minutes to get CANBUS
updated
Safety switch activated
Reset safety switch
Turbine will not start after repeated attempts.
Contact ATT support team (+45 29405023)
The display flash one time
Reset the safety switch
The battery symbol shows no voltage and flashes red
Check the electric plug outside the turbine
engine module is connected.
Check if any wire is damaged or loose to the
electric plug
Low airflow with 100% on the display
Check if the diesel filter is dirty
Unstable airflow in range 0 to 100%
Check the diesel system and ventilate the
system
Air flow high flashes on display
Change air filters
Air flow low flashes on display
Check air filters = install air filters
Rotor Blocked
Contact ATT support team (+45 29405023)