background image

7

Center of the
Upper Beam

Center of the
Lower Beam

Knockout

77

83

177

93

36

24

147

Mount bracket

Mount plate

117

ø42.7

88

39

30

66.7

83.5

Transmitter

Receiver

1.

Alarm Operation

To check the alarm operation, actually walk along as-

sumed intrusion path near the transmitter and receiver,

respectively and in-between as shown in the figure be-

low.

Check that the alarm LED lights up and the controller

receives the alarm signal when the beam is interrupted.

2.

Tamper Operation

Check that the controller receives an abnormal signal

when either of the transmitter and receiver cover is open.

11

TROUBLESHOOTING

Problem

False alarm is output fre-
quently.

No alarm is output even when
beam is interrupted.

Possible cause

An obstacle exists between transmitter and receiver.

Optical axis alignment is incomplete.

Installation condition is unstable.

Distance between transmitter and receiver exceeds
rated distance.

Beam is interfered with beam from another detector.

There is an electrical noise source in nearby area.

Sunlight enters receiver within 

±

3

°

 angle.

There is a highly reflective wall in parallel with beam.

Reflectance of floor surface is high.

Beam is interfered with beam from another detector.

Height of installation position is inappropriate.

Solution

Remove obstacle.

Perform optical axis alignment again to obtain 3V or
more tester level.

Stabilize installation condition.

Change installation position or use other detector with
suitable rated distance.

Take proper measure to avoid beam interference.

Change installation position.

Replace transmitter and receiver.

Adjust optical axis so that it is on the other side of
reflection surface.

Adjust optical axis so that it is on the other side of
reflection surface.

Take proper measure to avoid beam interference.

Change installation position to a proper height.

<Note>

If the trouble remains unsolved even after taking above solution, please consult the dealer of your purchase.

12

DIMENSIONS

This unit can be installed

to a pole with ø38.0 to

ø42.7 diameter.

10

OPERATION CHECK

Содержание NR30TD

Страница 1: ...dy carefully possible intrusion route and posture of an intruder to determine the installation position so that the beam is interrupted without fail Where there is not enough strength perform full reinforcement work before installing the detector If installed where not strong enough the detector may drop possibly resulting in its failure or damage and personal injury The beam spread angle of this ...

Страница 2: ...r the unit may break Do not apply a strong impact or vibration to the unit or a failure or damage may result 2 COMPONENTS The unit consists of the following major components 3 GENERAL DESCRIPTION The NR30TD NR60TD NR90TD outputs an alarm when the infrared pulse beam referred to as beam hereinafter emitted from its transmitter is not received by the receiver for a certain period of time beam interr...

Страница 3: ...m interruption time adjustment volume Used to determine the detection sensitivity 4 Tamper switch Detects open close of the cover 5 Vertical adjustment screw Used to make fine adjustment of optical axis vertically 6 Horizontal adjustment screw Used to make fine adjustment of optical axis horizontally 7 Twin lens Lens to transmit and receive the infrared beam 8 Scope Used to make rough adjustment o...

Страница 4: ...OM NC T T COM NC T T T T T T Tamper input b contact point Controller Power output Alarm input b contact point Receiver Transmitter Receiver Transmitter 3 EXAMPLE CAUTION Do not use aerial wiring or malfunction may re sult Be sure to cover outdoor wiring with pipes or an electrical shock or failure may occur Be sure to turn off the power during the wiring work or an electrical shock or failure may ...

Страница 5: ...installing the detector If installed where not strong enough the detector may drop possibly resulting in its failure or damage and personal injury After performing wiring make sure to fill the wiring hole with the sponge Failure to user the sponge properly may allow rainwater or the like to get inside the unit via the wiring possibly resulting in equipment failure or faulty opera tion 3 After pass...

Страница 6: ...meter of the receiver When the square marked level lamp in the table on the label is turned off it means alignment is completed If the lamp remains on adjust the horizontal and vertical adjustment screws of the transmitter and receiver until the square marked level lamp turns off 2 Fine adjustment Insert the tester stick into the tester hole in the receiver to check the tester voltage If the measu...

Страница 7: ... is interfered with beam from another detector There is an electrical noise source in nearby area Sunlight enters receiver within 3 angle There is a highly reflective wall in parallel with beam Reflectance of floor surface is high Beam is interfered with beam from another detector Height of installation position is inappropriate Solution Remove obstacle Perform optical axis alignment again to obta...

Страница 8: ...less Indoor 60m or less Indoor 120m or less Indoor 180m or less 50m sec 500m sec variable Horizontal direction 90 Vertical direction 5 Indoor Outdoor Transmitter about 380g Receiver about 380g Black Mansel approximation N1 0 14 OPTIONAL PARTS 15 MAINTENANCE Be sure to perform periodical inspection at least annually Check items Tester level Check that the tester level is 3V or more Power input volt...

Отзывы: