DETERMINING COVERAGE

This unit allows for 360 degree coverage mounting three(3) 120 degree optical assemblies.   You can adjust the mirrors either
simultaneously or independently.

1. SIMULTANEOUS SETUP

Rotate the adjusting plate to align V-shaped protrusion with the desired mounting height.  In this case, coverage of 20 meters
in diameter is achieved.

2. INDEPENDENT SETUP
     

1

Rotate the adjusting plate clockwise until V-shaped protrusion reaches‘‘ Free’’position.  Each mirror is then adjustable

independently.

2

Determine the rod position from the desired Mounting Height & Max. Range shown on the adjusting plate.

NOTE : Arrows and their area numbers are indicated on the label of the base unit.   Each arrow is centered in each coverage

of 120 degrees and its number stands for each one of three(3) areas.  The same numbers are also marked on the
adjusting plate of the sensor unit to match each other when fixed together.

Adjusting plate

Rod

Area number

V-shaped protrusion

Arrow and area number

Align the rod to C position
for 4 meter height and 8
meter coverage.

9

WALK TEST

1

Make sure that the dip switch 2 is ON.

2

Wait for 30 seconds after Power is turned on. (LED will flicker for 30 seconds.)

3

Make sure that LED lights when you walk in coverage.

4

In case LED does not light, adjust coverage and pulse count until it works properly.

In order to rotate the adjusting plate counterclockwise from ‘‘Free’’ position, all rods must be returned to the
center ends.

5

Содержание IR36E

Страница 1: ...y must be cut off during installation Keep power between 9 18 VDC anytime Attention Avoid intense shock and vibration After installation and setup make sure of performance and appropriate coverage of...

Страница 2: ...5 open when power is not supplied N C opens when the sensor unit is removed Contact Rating 30VDC 0 1A for Resistive Loads Please see 6 Functions for details 9 18 VDC Function Wire size 0 3mm2 or 0 65...

Страница 3: ...se unit 2Mount the base unit on ceiling and connect the wire to the unit 3Perform initial setup Please see 7 Initial setup for details 4Determine coverage Please see 8 Determining Coverage for details...

Страница 4: ...indicate the memory while both terminals are connected 4 Memory will be reset and the LED will be turned off when power is cut off or both terminals are disconnected 3 SELF DIAGNOSTIC CIRCUIT function...

Страница 5: ...heir area numbers are indicated on the label of the base unit Each arrow is centered in each coverage of 120 degrees and its number stands for each one of three 3 areas The same numbers are also marke...

Страница 6: ...other unit s Self Diagnostic circuit is activated 11 COVERAGE Side View The unit must be installed so that intruders will cross field of view Failure of this doing may end up mis alarm When the covera...

Страница 7: ...tive Loads 0 5 0 5 1 6 6ft sec 0 3 2 0 m sec Over 2 7 F 1 5 C difference against stable background at 3 3ft 1m sec under Environmental condition of 95 F 35 C 16 8 vertically Ceiling Indoor Mounting he...

Страница 8: ...movement of an intruder and activates an alarm control panel Being only a part of a complete system we can not take responsibility for any damages or other consequences resulting from an intrusion AT...

Отзывы: