background image

 
 
 

RMBC64-24D ELECTRONIC BATTERY CHARGER 

 

 

Functional Description (part 2). 

 
After the validation phase, a sense resistor connected between battery negative and the 
charger zero volts, (Vss) provides the necessary signal to the servo control loop which 
regulates the charging current. 
 
The charger unit consists of two banks of sixteen individual chargers, each delivering 
0.3C at full charge (700mA) to each internal pack. 
 
Should one or more of the charging cards fail, the unit will still be able to charge which 
gives the RMBC64-24D a large redundancy capability. 
 
 
 

Содержание RMBC64-24D HAWK

Страница 1: ...RMBC64 24D HAWK 3 STAGE BATTERY CHARGER OPERATORS MANUAL 2012...

Страница 2: ...RMBC64 24D ELECTRONIC BATTERY CHARGER INDEX Page Handling Requirements 1 Installation 1 Specifications 2 Overview 3 Functional Description 3 Operation 5 Trouble Shooting 11...

Страница 3: ...tch is in the OFF position Lower back flap by twisting anti clockwise Zuse fasteners to expose mains input socket and ventilation fans Ensure both charger and mains is switched OFF before connecting p...

Страница 4: ...570mm H x W x D Battery charge state Any level from flat to full Time between full charge operation 1 hour Time between full charge operation means that if the operator has fully charged the battery i...

Страница 5: ...l be on with the top row of green LEDs flashing This indicates that all the charging circuits are operating correctly within the bank When the charge cycle is complete the red LEDs within that bank wi...

Страница 6: ...Vss provides the necessary signal to the servo control loop which regulates the charging current The charger unit consists of two banks of sixteen individual chargers each delivering 0 3C at full cha...

Страница 7: ...HAWK batteries together Various combinations of battery charge can be selected which include A Single battery on full charge B Two batteries on full charge C One battery on full charge and second batt...

Страница 8: ...rcuits have been internally checked and they are operating correctly After the charge procedure has been initialized the charge indicators will start to flash and continue to flash until the battery i...

Страница 9: ...ators representing the selected battery will illuminate and remain constant for as long as it takes to charge the appropriate cells When the cells are fully charged the appropriate status indicators w...

Страница 10: ...ition informs the operator when the trickle charge system is in operation by emitting an audible intermittent bleep This alert can also be used to remind the operator when the batteries have completed...

Страница 11: ...rocedure the LED will go out informing him her that the trickle procedure has stopped After the HAWK battery has been fully charged the main charging system turns off and the trickle charge commences...

Страница 12: ...or The power indicator lamp informs the operator when illuminated that mains power is being supplied to the charger 12 Fuse An 8AMP Anti Surge fuse is fitted to this charger WARNING THIS CHARGER IS FO...

Страница 13: ...p fuse not illuminated Check power from source Charger has power WARNING CHARGER MUST BE Neon mains light Charger fuse blown SWITCHED OFF FROM THE MAINS illuminated but not BEFORE OPENING FUSE HOLDER...