6
June 2004
Seiko PS
A-66-ST
Keypad LED Operation and
Printer Status Conditions
The keypad LEDs provide a more detailed reporting
of system status. The Table below lists the status
of the keypad LEDs in a variety of status which are
defined following.
Although there are a variety of error conditions which
can occur, most printer errors are a result of the
printer running out of paper or the operator lowering
the Platen lever. This section lists the possible error
which can occur, and how the condition is remedied.
UNIT FLUSHED:
This condition results
when the printer has improperly loaded or firmware
is not installed. Remedy the condition by properly
reloading new firmware.
PAPER OUT:
This condition results
when the printer detects that paper is not present.
The printer scans for a paper out condition at all
times. Remedy the condition by loading a new paper
stack.
Condition
Status LED
Error LED
Unit Powered Off
OFF
OFF
Unit Ready
ON
OFF
Unit Flushed
ON
ON
Paper Out
OFF
ON
Platen Down
OFF
ON
Temperature Error
OFF
Med Blink
Voltage Error
OFF
Slow Blink
Print Head Error
ON
Fast Blink
Mising Black Index Mark ON
Fast Blink
Paper Jam
ON
Fast Blink
H
ANDLING