Atrix Omega Supreme Plus Forensic Series Скачать руководство пользователя страница 2

Forensic VACUUM INSTRUCTIONS 

 

Forensic OPERATION INSTRUCTIONS 

 

1.

 

Release the two front fasteners and open the lid.  

2.

 

Remove hose, power cord, and factory sealed forensic filter and crevice tool from cover storage area. 

3.

 

Remove the orange plug from the filter cartridge and store in unit. 

4.

 

Slide one end of the super flex hose into the filter cartridge. 

5.

 

*Remove forensic filter and then remove red caps and attach hose and crevice tool. 

6.

 

Plug the female end of the power cord into the receptacle on the vacuum. 

7.

 

Close lid and latch securely. 

8.

 

Plug the power cord into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. 

9.

 

Turn on the power switch. 

10.

 

 These vacuums have a factory installed resettable Thermal Cutout (TCO) for added operator and motor safety.  If the unit gets too hot, the vacuum will shut down for approx. 20 minutes.  Turn the 
on/off switch to the off position, and turn back on in approximately 20 minutes.  Your hose may be clogged, or it may be time to install a new filter. 

 

 

*

PROCEDURE 

Prepare Vacuum for Use 
Tamper proof evidence tape is used to seal the evidence filter. Do not attempt to open the filter chamber. Any assembly 
with disturbed evidence seals should be discarded. 
1. Remove the round red vinyl caps from both ends of the filter. Keep these caps for later use. Attach the appropriate 
tool to the tapered end of the filter. 
2. Attach the filter directly to your vacuum’s flexible hose. Proceed with evidence collection. Monitor the amount of evidence collected through the 
chamber’s clear tube, and replace filters as needed. 
3. After collection is complete or the filter is full, remove the tool from the filter. Remove the filter from the 
vacuum sweeper and replace both end caps. This effectively seals the evidence into the trace evidence filter 
assembly. 
4. Fill out the form printed on the self-sealing evidence/property bag in which the filter assembly will be packed. 
5. Initial the evidence tape seal on filter assembly. 
6. Place the filter and applicable tool into the bag. 
7. Remove the release liner from the flap of the bag. (The release liner is a plastic strip that protects the adhesive.) 
8. Fold along the line indicated on the bag. Press flap and bag together along the line of adhesive to form seal. The 
bag is now sealed. 
9. Tear off the receipt tag from the end of the bag and retain for your records. 
10. Forward sealed evidence bag to appropriate crime laboratory.

 

 

INTRODUCTION 
The Trace Evidence Collection Filter is designed and manufactured 
specifically for the collection of >90% of 3-10 micron particle 
evidence at crime scenes. 
The evidence filters offer one-time use to prevent any possibility 
of contamination from one area to another. These filters are sealed 
at the factory, and these seals must not be disturbed either before 
or after evidence is collected. The seal may be broken only by the 
laboratory technician. 
CAUTIONS 
• The trace evidence filter is intended for one use only. DO NOT REUSE THIS FILTER or CREVICE TOOL. 

Содержание Omega Supreme Plus Forensic Series

Страница 1: ...nect to a properly grounded outlet only See Grounding Instructions 17 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that...

Страница 2: ...2 Attach the filter directly to your vacuum s flexible hose Proceed with evidence collection Monitor the amount of evidence collected through the chamber s clear tube and replace filters as needed 3 After collection is complete or the filter is full remove the tool from the filter Remove the filter from the vacuum sweeper and replace both end caps This effectively seals the evidence into the trace...

Страница 3: ...le 25 Power Cord 110V OVPE004B Detachable 8 European Power Cord 66021A Please contact Atrix for appropriate replacement parts 1 800 222 6154 www atrix com Email Sales atrix com Forensic Vacuum WARRANTY INFORMATION For warranty service information please contact your local distributor Warranty Service Information For warranty service information please contact your local distributor To the original...

Страница 4: ...MPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Limitation of Liability ATRIX WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR ANY COINCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES OR ECONOMICAL LOSS BASED UPON BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT LIABILITY IN TORT OR ANY OTHER LEGAL THEORY EVEN IF ATRIX HAS BEEN ADVISED ...

Отзывы: