Atrix Biocide ATIBCV Скачать руководство пользователя страница 3

 

Warning: 

Operating a machine without observing all labels, decals, etc., could result in injury or 

 

damage. Read all machine labels before attempting to operate the machine. Make sure all of the 

 

labels are attached or fastened to the machine. Get replacement labels and decals from the  

 

manufacturer’s distributor. 

  

Warning: 

Electrical components can “short-out” if exposed to water or moisture. Keep the electrical 

components of the machine dry. Always store the machine in a dry area. 
 
 

Warning: 

Use of this machine to move other objects or to climb on could result in injury to the opera-

tor or damage to the machine. Do not use this machine as a step or furniture. Do not allow to be used 
as a toy. Close attention is necessary when used by or near children. 

 

Warning: 

Moving parts of this machine can cause injury and/or damage. Keep hands, feet, loose 

clothing, hair, fingers, and all parts of the body away from openings and moving parts. 
 

 

Warning: 

Electrocution could occur if you handle the plug or appliance with wet hands. Do not handle 

plug or appliance with wet hands. 
 

 

Warning: 

Do not use without dust bag and or filters in place. 

 
 

Warning: 

Rotating fan blades inside the cover. Before opening cover, switch off machine. Wait until 

the fan/brush stops completely or dust and debris may be ejected. 
 
 

Warning: 

If the machine is not working properly, has been dropped, damaged, left outdoors, or 

dropped into water, return it to an Authorized service center. 
 
 

Warning: 

Damage could occur to machine if openings are blocked. Do not put any object into       

openings. Do not use any opening blocked: keep free of dust, lint, hair, and anything that may reduce 
air flow. 
 

Warning: 

Injury could occur to the operator or the machine if used without the dust bag and/or filters 

in place. Do not use the machine without the dust bag and/or filters in place. 
 
 

Warning: 

Injury to the operator and/or damage to the machine could occur when cleaning on stairs, 

unless caution is used. Use extreme caution when cleaning on stairs. 
 
 

 

Warning: 

To reduce the risk of electrical shock, always use a 3-wire electrical system connected to 

the electrical ground. Whenever possible connect the machine to an outlet protected by a ground fault 
interrupter (GFCI). See “Grounding Instructions.” 
 

 

SAVE THESE INSTRUCTIONS 

 
 

Содержание Biocide ATIBCV

Страница 1: ...BIOCIDE ANTIMICROBIAL DRY VACUUM Model ATIBCV ...

Страница 2: ...s manual explained fully before attempting to operate this machine DANGER Operating a machine that is not completely or fully assembled could result in injury or property damage Do not operate this machine until it is completely assembled Inspect the machine carefully before operation Use only as described in this manual Use only the manufacturer s recommended attachments DANGER Machines can cause...

Страница 3: ...dle plug or appliance with wet hands Warning Do not use without dust bag and or filters in place Warning Rotating fan blades inside the cover Before opening cover switch off machine Wait until the fan brush stops completely or dust and debris may be ejected Warning If the machine is not working properly has been dropped damaged left outdoors or dropped into water return it to an Authorized service...

Страница 4: ...d to the electrical ground Whenever possible connect the machine to an outlet protected by a ground fault interrupter GFCI Warning Do not cut remove or break the ground pin If the outlet does not fit the plug consult your electrical contractor Warning Have worn cut or damaged cords and plugs replaced by an authorized service person Warning If it becomes necessary to use an extension cord to reach ...

Страница 5: ... paper bag to tank inlet deflector See Figure 1 2 Ensure that the cartridge filter is securely attached to the bottom of the vacuum head See Figure 2 3 Stretch treated pre filter over the HEPA cartridge filter See Figure 2 4 Attach filter retainer using the 2 mounting screws 5 Place vacuum head onto the tank and secure it with the two clamps 6 Insert hose into the tank inlet until it locks in plac...

Страница 6: ... ATIBCV3935 Spacer 1 13 ATIBCV3464 Terminal Strip 1 14 ATIBCV1050 Screw 5x35 6 15 ATIBCV3383 Cap 1 16 ATIBCV2738SL Cover Motor 1 17 ATIBCV0138 Strain Relief 1 18 ATIBCVH2 Filter HEPA 1 19 ATIBCV2627 Screw 5x40 6 20 ATIBCV2591SL Plate Motor 1 21 ATIBCV7585TP Motor 1 22 ATIBCV7630 Gasket Motor 1 23 ATIBCV7635 Sound Dampener 1 24 ATIBCV3190GSL Base W Gasket 1 25 ATIBCV7765 Support Filter 1 26 ATIBCV2...

Страница 7: ...Assembly Item Part Description Qty 1 ATIBCV2652A Inlet Cover 1 2 ATIBCV2846 Gasket Inlet 1 3 ATIBCV2593 Deflector 1 4 ATIBCV2586 Inlet Cover Base 1 5 ATIBCV21153 Tank 1 6 ATIBCV1026 Screw 5x30 4 7 ATIBCV1302 Rivet 4 8 ATIBCV1847 S Latch 2 ...

Страница 8: ...8 Tank and Cart Assembly ATIBCV Cart Assembly Item Part Description Qty 1 ATIBCV20744 Base 1 2 ATIBCV0558 Caster Swivel 2 3 ATIBCV1005 Screw M5x14 4 4 ATIBCV6043 Wheel Rear 2 5 ATIBCV6044 Hub Cap 2 ...

Страница 9: ... Tool 1 3 ATIBCV0004 Round Brush 1 4 ATIBCV1685VHA Hose 1 5 ATIBCV6240VHA Wand Straight 2 6 ATIBCV6158VHA Wand Curved 1 7 ATIBCV0632 Double Use Floor Brush 1 Filters ATIBCVBAG Paper Bags 5 pkg ATIBCVH1 Hepa Filter Cartridge Main ATIBCVH2 Hepa Filter Cartridge Exhaust ATIBCVSF Pre Filter Treated ...

Страница 10: ...al warranty period Atrix International will furnish and charge for replacement parts including transporta tion to the original owner If the part is returned within 30 days and is found defective the owner will be credited for the cost of the replacement part including shipping and handling Wear items exempt from warranty include belts carbon brushes power cords wheels brushes pads handle grips fil...

Отзывы: