Atrie DB-120 WL User Manual
Page 21 / 25
current dynamic IP address. The amount of time is in units of minutes; the default value is 3600 minutes (60
hours).
Note: If you change the start or end values, make sure the values are still within the same subnet as the
Gateways IP address. In other words, if the Gateway’s IP address is 192.168.1.1 (default) and you change
the DHCP start/end IP addresses to be 192.128.1.2/192.128.1.100, you will not be able to communicate to
the Gateway if your PC has DHCP enabled.
2.
To Enable the DHCP Relay mode, choice "Enable DHCP Relay" and input the IP of DHCP Server.
When the Gateway is configured as DHCP relay, it is responsible for forwarding the requests and
responses negotiating between the DHCP clients and the server.
3.
To Disable the DCHP mode, choice "Sever and Relay Off".
By turning off the DHCP server and relay the network administrator must carefully configure the IP
address, Subnet mask and DNS settings of every computer on your network. Do not assign the same IP address
to more than one computer and your Gateway must be on the same subnet as all the other computers.
4.2 PASSWORD CONFIGURATION
When logging in the WEB-UI of the Gateway, the system requires the username and password to validate
access permission. The default account is
"admin"
and the default password for this account is
"password"
.
The user names are permanent. But the password can be changed in the
"User Management
".
Attention: Please remember the password after change otherwise you will not be able to change
configuration after saving.
It will log out automatically, if the user doesn’t do any thing after logging in the Gateway for sometime.
The
"Idle Timeout"
can be configured in
"User Management"
.