background image

 

8. NOTES 

 

Do not store or operate the meter in high temperature 

or humidity. 

 

Remove the battery when the meter is to be stored for 

long periods of time to avoid battery leakage. 

 

9. ACCESSORIES 

 

User manual 

 

  9V Battery   

 

  Carry Case 

 

 

Содержание PT-500

Страница 1: ...USER MANUAL PT 500 HI ACCURACY THERMOMETER Please read this user manual thoroughly before using this unit and keep it for your future reference ...

Страница 2: ...CONTENTS 1 Safety Environmental Maintenance 1 2 Features 2 3 Specifications 3 4 Meter Description 4 5 LCD Display Description 5 6 Operating Instructions 6 7 Button Functions 7 8 Notes 8 9 Accessories 8 ...

Страница 3: ......

Страница 4: ...ed in this manual ENVIRONMENT CONDITIONS Altitude up to 2000 meters RH 90 Non Condensation Operating Temperature 20 C to 60 C MAINTENANCE Repairs or servicing not covered in this manual should only be performed by qualified personnel Wipe the unit with a dry soft cloth Do not use abrasives or solvents on this instrument Complies with EMC ...

Страница 5: ...ntact thermometer with PT 100 input It is widely used for Hi Accuracy Applications Precise measurement PT 100 input Selectable 0 1 C or 0 01 C Resolution Large 34mm backlit LCD display DATA HOLD function C F selection Auto power off ...

Страница 6: ...IFICATIONS Range 200 C to 400 C or 328 0 to 752 0 F Resolution Selectable 0 1 C or 0 01 C 0 01 C 80 to 200 C 0 1 C 200 C to 400 C Accuracy 0 05 C 80 C to 200 C 0 1 C Others Power 1 x 9V PP3 Battery Weight 292g ...

Страница 7: ...4 4 METER DESCRIPTION PT 100 input connector LCD display C F selection button Resolution and measuring range selection button Hold button Backlight button Power ON OFF button Battery Compartment Cover ...

Страница 8: ...5 5 LCD DISPLAY DESCRIPTION Sensor Type Low battery Indicator Temp units icon Reading Data Hold Icon Auto power off enabled Icon ...

Страница 9: ... battery and close the battery compartment cover 2 Connect a PT 100 probe 3 Power on the meter to start measurement Note When the low battery icon appears replace the meter s battery During measuring the tip of the temperature sensor must be fully connected to the object to be measured ...

Страница 10: ...f the backlight 3 Measurement Unit Button When powered on press the measurement unit button to toggle between C or F measurement unit 4 Level Button When powered on press the Level button to toggle the resolution to 0 01 C with a range of 80 C to 200 C or 0 1 C resolution with a range of 200 C to 400 C 5 Hold button When powered on press the hold button to freeze the reading on the display Press a...

Страница 11: ...o not store or operate the meter in high temperature or humidity Remove the battery when the meter is to be stored for long periods of time to avoid battery leakage 9 ACCESSORIES User manual 9V Battery Carry Case ...