6.    LCD Display Description 

1. Low battery indication   

2. MAX/MIN icon 

3. Humidity icon 

4. Humidity reading 

5. 

/

 temperature icon 

6. Temperature reading 

7. Auto power off icon 

8. Hold icon 

 

7.    Operation Instruction 

(1) 

Open battery cover and install a 9-volt battery in the battery compartment. 

(2) 

Power ON

Turn the meter on by pressing "

" button for 1 second until the LCD is lit, then release 

the button. 

(3) 

Power OFF

Turn the meter off by pressing and holding "

" button for approx. 3 seconds until the 

LCD is switched off, then release the button. 

(4) 

When the low battery icon "

" appears, replace the meter's battery.   

(5) 

Auto power off icon, the meter will automatically turn off after approx. 15 minutes of inactivity. 

(6) 

LCD  Backlight:  After  turning  the  meter  on,  momentarily  press  the  "

"  button,  the  backlight  will 

come on; it will automatically turn off after approx. 30 seconds of inactivity. 

(7) 

Hold & MAX/MIN Function 

HOLD: 

After turning the meter  on, press "

" button. The "HOLD" icon will appear  on the LCD, 

which indicates the data is frozen. To release the held reading, press the button again.   

MAX/MIN:

  Press  and  hold  "

"  button  for  at  least  3  seconds  until  "MAX"  icon  appears  on  the 

LCD to view the  MAX reading since power on; press the button  again, the "MIN" icon appears  on the 

LCD to  view the  MIN reading  since power  on. To  exit the  MAX/MIN mode, press  and  hold the  button 

"

" for 3 seconds. 

(8) 

/

 temperature units   

In  the  OFF  mode,  press  and  hold  the  "

"  button,  then  power  the  meter  on,  after  the  LCD 

displays, release the button, the temperature units 

/

 will alternate. 

(9) 

Calibration 

The recommended calibration period is one year. 

8.    Notes 

 

 

This meter has already been calibrated before delivery. 

 

 

Repairs or servicing should only be performed by ATP Instrumentation Ltd. 

 

 

Remove the battery when the meter is to be stored for long periods of time to avoid battery leakage. 