2.1

 

Overview 

 
The

 

SE59XX is an industrial

 

Ethernet serial device server which acts as a gateway for communications between 

Ethernet  (TCP

/

UDP)

 

port  and  RS

-

232

/

RS-422/RS-485  port

The  information  conveyed  by  the  SE59XX  model  is 

transparent to both host computers (Ethernet) and serial devices (RS

-

232/RS-422/RS

-

485).

 

Data coming from the 

Ethernet port is sent to the designated RS

-

232/RS-422/RS

-

485 port, and data received from RS

-

232/RS-422/RS

-

485 port is sent to the Ethernet port, allowing full

-

duplex and bi

-

directional communication

In the computer

-

aided 

manufacturing  or  industrial  automation  areas,  field  devices  can  directly  connect  to  an  Ethernet  network  via  the 
SE59XX model

In normal PCs or laptops, a virtual COM port can be created using our vitual COM software to fetch 

serial data from SE59XX remotely over Ethernet

Note that SE5901 model does not support RS-422 and 4-wired RS-

485.  

With the SE59XX model, it is possible to communicate with a remote serial device over the LAN or even over the 
Internet, which dramatically increases reachability and scalability

 

 
Figure 2.1 illustrates an example of multiple devices connected to the Industrial Serial Device Server

A PC connects 

to  the  Industrial  Serial  Device  Server  via  Ethernet  interface,  and  a  monitored  device  reports  to  Industrial  Serial 
Device Server

 

via RS

-

232/RS-422/RS

-

485 interface

It is possible to have multiple PCs connected into the same 

Industrial  Serial  Device  Server  through  TCP  or  UDP  transport  protocols,  as  well  as  multiple  monitored  devices 
connected via RS

-

232/RS-422/RS

-

485 to Industrial Serial Device Server

 

 

 

Figure 2.1 An Application of SE59XX Industrial Serial Device Server with Multiple Devices 

 

2.2

 

Features 

 
The  SE59XX  Industrial  Serial

 

Device  Server  Series  share  the  same  software  platform  on  different  available 

hardwares. It provides 

 

Flexible hardware platform, in different port variants based on Your needs 

 

TCP Server

/

Client, UDP, Virtual COM and Tunneling modes supported 

 

Remotely monitor, manage, and control industrial field devices 

PC 

SE59XX 

PLC

/

IO devices 

Содержание SE59 Series

Страница 1: ...ss mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer...

Страница 2: ...SE59XX Industrial Device Server Series User Manual V 1 0 SE59XX Series Industrial Device Server Series User Manual V1 0 September 25th 2017 Atop Technologies Inc...

Страница 3: ...or ease of navigation For example click on any item listed in the Table of Contents to go to that page Published by Atop Technologies Inc 2F No 146 Sec 1 Tung Hsing Rd 30261 Chupei City Hsinchu County...

Страница 4: ...ution All rights including rights created by patent grant or registration of a utility model or design are reserved Disclaimer We have checked the contents of this manual for agreement with the hardwa...

Страница 5: ...17 4 2 Configuring through Web Interface 19 4 3 Configuring Automatic IP Assignment with DHCP 22 4 4 Web Overview 22 4 5 Network Settings 24 4 6 Serial 25 4 6 1 COM Port Overview 26 4 6 2 COM Configur...

Страница 6: ...ation 78 6 1 3 Installation 78 6 1 4 Uninstallation 78 6 2 Enable VCOM in Serial Device servers and Select VCOM in Windows 78 6 2 1 Enable VCOM in Serial Device servers 78 6 2 2 Running Serial IP Soft...

Страница 7: ...application via the subnet to subnet connection 34 Figure 4 23 An example of host host application via the subnet to subnet connection 34 Figure 4 24 IPsec Tunnels Web Page under IPsec Setting Menu 3...

Страница 8: ...are 87 Figure 6 14 VCOM Authentication failed due to Missing Username Password 88 Figure 6 15 VCOM Authentication failed due to incorrect Username and or Password 89 Figure 6 16 VCOM Authentication fa...

Страница 9: ...nt for 5 Pin Terminal Block to RS 232 RS 422 RS 485 Connectors 102 Table 7 10 MB5908 16 Pin Assignment for RJ45 to RS 232 RS422 RS 485 Connectors 103 Table 7 11 SE59XX Pin Assignment for RJ 45 Connect...

Страница 10: ...toponline com 1 3 Supported Platform This manual is designed for SE59XX Industrial Serial Device Server Series and that series only 1 4 Manufacturers FCC Declaration of Conformity Statement NOTE This...

Страница 11: ...485 With the SE59XX model it is possible to communicate with a remote serial device over the LAN or even over the Internet which dramatically increases reachability and scalability Figure 2 1 illustr...

Страница 12: ...IP30 protection for wall or DIN Rail mount Wide range power supply input between 9 48 VDC Caution Beginning from here extreme caution must be exercised Never install or work with electricity or cablin...

Страница 13: ...pin 5 08mm lockable Terminal Block SE5916A Documentation 1 Hardware Installation Guide Warranty card is included Note Notify your sales representative immediately if any of the above items is missing...

Страница 14: ...41G SFP Transceiver 1250Mbps 1310nmDFB Single mode 30km 3 3V 40 85 C LM38 A3S TI N 50708051G SFP Transceiver 155Mbps 1310nmLED Multi mode 2km 3 3V 40 85C LS38 A3S TI N 50709431G SFP Transceiver 155Mbp...

Страница 15: ...SE59XX Industrial Device Server Series User Manual Getting Started SE5901B SE5908 16...

Страница 16: ...d inside the product Atop will not be liable for any damages to property or personal injuries resulting from the installation or overall use of the device Do not attempt to manipulate the product in a...

Страница 17: ...P Default Settings Parameter Default Values Security User Name admin Password default Serial COM1 RS 232 9600 bps 8 data bits No Parity bit 1 stop bit No Flow Control Packet Delimiter timer Auto COM2...

Страница 18: ...ed via broadcast packets Device Management Utility will automatically detect your SE59XX device and list it on Device Management Utility s window Alternatively if you did not see your SE59XX device on...

Страница 19: ...ure 4 4 The default username is admin while the default password is default After clicking on the Authorize button a notification window will pop up as shown in Figure 4 5 and some device may be resta...

Страница 20: ...er for configuring by entering the device s IP address default IP address is 10 0 50 100 in the URL field of your web browser An authentication will be required and you will have to enter the username...

Страница 21: ...trial Device Server Series User Manual Configuration and Setup Figure 4 7 Authentication Required for Accessing Web Interface Figure 4 8 Warning Pop up Window for Changing or Resetting Password from D...

Страница 22: ...ial Device Server Series User Manual Configuration and Setup Figure 4 9 Overview Web Page of SE59XX Industrial Serial Device Server Figure 4 10 Map of Configuring Web Page on SE59XX Industrial Serial...

Страница 23: ...d Network Gateway to LAN interface You can simply check the DHCP Obtain an IP Automatically checkbox in the Network Setting dialog as shown in Figure 4 3 using Atop s Device Management Utility and the...

Страница 24: ...he version of the kernel firmware of the device o AP Version is the value of the version of the application firmware of the device o Bootloader Version is the version of the program that loads the ope...

Страница 25: ...ou can select the default gateway network for your serial device server You can either select LAN1 or LAN2 by clicking on the corresponding radio button Fourth DNS Server part is where you can specify...

Страница 26: ...ial communication with COM port s Note that SE59XX series can have up to four COM ports COM1 COM2 COM3 and COM4 while typical SE5901 model will have only one COM port COM1 Figure 4 13 shows the Serial...