Atop RHG7528 Series Скачать руководство пользователя страница 2

LED

 

Color

 

State

 

Description

 

P

W

R1/

 

P

W

R2

 

Green

 

O

n

 

Power is supplied from P

W

R1/P

W

R2

O

ff

 

No power input detected from P

W

R1/P

W

R2

A

LM

 

Red

 

O

n

 

Alarm is triggered 

b

y user defined e

v

ents

O

ff

 

Alarm is not triggered 

b

y user defined 

events

RUN

 

Green

 

Blinking

 

AP firmware is running  normally

O

ff

 

System is not ready or halt

Ring

 

Green

 

O

n

 

All rings in normal  condition or 

CC

hain in 

normal condition

Blinking

 

Ring in protection state or a port is link down 
in 

CC

hain

O

ff

 

Ring is disa

b

led or 

CC

hain is disa

b

le

 

R.

M

 

Green

 

O

n

 

T

he de

v

ice is a 

M

aster of the 

E

RPS Ring or 

iA-Ring or a Head of CChain

Blinking

 

T

he de

v

ice is a 

T

ail of 

CC

hain

O

ff

 

T

he de

v

ice is a Sla

v

e of the 

E

RPS Ring or 

i

A-

Ring or a 

M

em

b

er of 

CC

hain

 

10G

 

O

LED

 

Panel

 

Green

 

O

n

 

Port is linked

Blinking

 

D

ata is transmitting  on this port

O

ff

 

No data is transmitting

 

L

AN

 

Am

b

er

 

O

n

 

E

thernet  is linked at 1000

Mb

ps

 

Blinking

 

E

thernet  is linked at 100

Mb

ps

O

ff

 

E

thernet  is linked at 10

Mb

ps

Green

 

O

n

 

E

thernet  is linked 

Blinking

 

Ethernet is active and data is being transmitted

O

ff

 

E

thernet  is not linked

S

F

P

 

(

1G

)

 

Am

b

er

 

O

n

 

E

thernet  is linked at 1000

Mb

ps

Blinking

 

E

thernet  is linked at 100

Mb

ps

O

ff

 

E

thernet  is linked at 10

Mb

ps

Green

 

O

n

 

E

thernet  is linked 

Blinking

Ethernet is active and data is being transmitted

O

ff

E

thernet  is not linked

S

F

P

PoE

MACsec

(

10G

)

Am

b

er

O

n

E

thernet  is linked at

 10GMbps 

Blinking

E

thernet  is linked at 10

00Mbps

O

ff

E

thernet  is linked at 1

00Mbps

Green

O

n

E

thernet  is linked 

Blinking

Ethernet is active and data is being transmitted

O

ff

Ethernet is not linked

Amber

O

n

Power is being supplied to a Powered 

Device (PD)

O

ff

Power is not supplied to a Powered Device(PD)

Blue

O

n

MACsec active on that port

Blinking

 

Ethernet is active and data is being transmitted

O

ff

Ethernet is not linked

If  the  device  requires  servicing  of  any  kind,  you  may  need  to  disconnect  and 
remove it from its mounting. The initial installation should be done in a way that 
makes this as convenient as possible.
■ Voltage/Power lines should be properly insulated as well as other cables. Be 

careful when handing the so as to not trip over

■ Do not under any circumstance insert foreign objects of any kind into the heat 

dissipation holes located in the different faces of the device. This may not only 
harm the internal layout but might cause harm to you as well.

■ Do not under any circumstance open the device for any reason. Please 

contact your dealer for any repair needed or follow the instructions on section 

of your User’s Manual.

Field Maintenance and Service

Attention

1. It is recommend to use at least a 20 AWG cable for the AC power input. 
    It is suggested the cable to be resistant to at least 85°C temperature on the 

    power connector.

2. If the equipment is used in a manner not specified by the manufacturer, the 
    protection provided by the equipment may not be impaired.
3. Clean the device with dry or humid (water) soft cloth.
4. Before powering on the device, the Functional Ground (Grounding Screw) 
    shall be connected to the ground.
5. If the device is AC please connect PWR1. If AC redundant, connect PWR1 
    and PWR2 to the 100~240V AC power source. This power input manages 
    the full device functions except from PoE.
6. If the device is DC powered, please connect DC1 and DC2 to the DC 

    power supply.

7. If PoE is going to be used, also POE PWR1 and POE PWR2 should be
    connected to 48~57 VDC power supplies). In order to avoid overheat and 
    damages to the internal components the user should follow the below

    guidelines:

     ■ Total PoE power needed is <= 360W: connect to either power supply 

   

   POE PWR1 or POE PWR2 or both.

     ■ Total PoE power needed is >360W but <=720W (max): connect to both 

    

  POE PWR1 and POE PWR2 in order to avoid overhead.

8. POE PWR1 or POE PWR2 support maximum input 360 W.
9. POE PWR1 / POE PWR2 , + / - pins should be connected in same PWR input
    Terminal block, please don’t cross-connect.

Environmental Limits

■ Operating Tem perature: -40 to 75°C (-40 to 167°F)
■ Storage Temperature: -40 to 85°C (-40 to 185°F)
■ Ambient Relative Humidity: 5 to 95%, 55°C (non-condensing)
■ Altitude: up to 2,000 m
■ Housing Protection : IP 30

Front View

Back View

Top View

Site View

482,6

6

464,5

31,8

440

340

44

Customers shall always obtain an authorized "RMA" number from Atop before 
shipping the goods to be repaired to Atop. When in normal use, a sold product 
shall be replaced with a new one within 3 months after purchase. The shipping 
cost from the customer to Atop will be reimbursed by Atop.
After 3 months and still within the warranty period, it is up to Atop whether to 
replace the unit with a new one; normally, as long as a product is under warranty, 
all parts and labor are free of charge to the customers.
After  the  warranty  period,  the  customer  shall  cover  the  cost  for  parts  and 
labor.Three months after purchase, the shipping cost from the customer to Atop 
will not be reimbursed, but the shipping cost from Atop to the customer will be 
paid by Atop.

Atop  shall  not  be  held  responsible  for  any  consequential  losses  from  using Atop’s 

product.

Warranty Policy

The warranty certification will not be effective until an authorized stamp issued by 

Atop’s overseas agents.
Purchase Date:                /               /                 (yyyy/mm/dd)
Serial Number

Product Categories

Warranty

Warranty

Product Categories

Media Converters
Embedded Device Servers

Ethernet Switches
Wireless
Serial Device Servers
Modbus Gateways

DIN-Rail Power Supplies

Power Adaptors

Antennas

Other Accessories

Warranty Conditions

RMA and Shipping Costs Reimbursement

Limited Liability

 1. Please contact your local dealers or Atop Technical Support Center at the  

     following numbers.

     + 886-3-550-8137 (Atop Taiwan)

     + 86-21-6495-6232 (Atop China)

2. Please report the defected problems via Atop’s Web site or E-mail account

    Web Site

www.atop.com.tw, e-mail

[email protected] 

    Web Site

www.atop.com.cn, e-mail

[email protected]

3. Company Addr: 2F, No. 146, Sec. 1, Tung-Hsing Rd., Jubei, Hsinchu 30261, 

    Taiwan, R.O.C.

    Manufacturer Addr: 1st FL 30 R&D RD II,SCIENCE-BASED INDUSTRIAL  

    PARK,HSINCHU 300 TAIWAN, R.O.C

Atop Customer Services and Supports

Products  supplied  by  Atop  Technologies  are  covered  in  this  warranty  for 
sub-standard  performance  or  defective  workmanship.  The  warranty  is  not, 
however, extended to goods damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake
(c) Use of unqualified power supply, connectors, or unauthorized parts/kits
(d) Replacement with unauthorized parts

Warranty Period

─  Any changes to this material will be announced on Atop website.  ─

Отзывы: