![Atop EH9711 Series Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/atop/eh9711-series/eh9711-series_user-manual_3004814022.webp)
Industrial Managed
Ethernet Switch – EH9711
User Manual
Page
22
of
223
Figure 2.10 Webpage to Configure System NTP
The detailed description of each field is provided in Table 2.5.
Table 2.5 Descriptions of the NTP Settings
Label
Description
Factory Default
Mode
Select to enable or disable an automatically setting of the
device time. This option will disable or enable network
time protocol (NTP) daemon inside the managed switch
which allows this managed device to synchronize its clock
with other NTP servers.
Disabled
Server 1
Sets the first IP or Domain address of
NTP Server
; e.g.,
time.nist.gov.
NULL
Server 2
Sets the second IP or Domain address of NTP Server.
Switch will locate the 2nd
NTP Server
if the 1st NTP
Server fails to connect; e.g., time-A.timefreq.bldrdoc.gov
NULL
Server 3
Sets the third IP or Domain address of NTP Server. Switch
will locate the 3rd
NTP Server
if the 2nd NTP Server fails
to connect.
NULL
Server 4
Sets the fourth IP or Domain address of NTP Server.
Switch will locate the 4th
NTP Server
if the 3rd NTP
Server fails to connect.
NULL
Server 5
Sets the fifth IP or Domain address of NTP Server. Switch
will locate the 5th
NTP Server
if the 4th NTP Server fails
to connect.
NULL
2.1.4
Time
This
Time
webpage allows the user to configure the time zone and daylight saving for the managed switch. There are three
setting parts within this webpage:
System Time Configuration, Time Zone Configuration
, and
Daylight Saving Time
Configuration
.
The first part :
System Time Configuration,
users are allowed to set the device’s system time by manual. Table 2.6
summarizes the descriptions of options in system time configuration
The second part :
Time Zone Configuration
, users are allowed to set the device’s time zone. By clicking the drop-down list
of
Time Zone
field, users can select the device’s local time zone or
Manual Setting
option
.
In the
Hours
and
Minutes
fields, users can enter the number of hours and minutes of the device’s time that is offset from the local time zone when users
selected
Manual Setting
option. Table 2.7 summarizes the descriptions of options in time zone configuration.