Atop Industrial Unmanaged Ethernet Switch
EH2006 / EH2005-Fs / EH2005-Fm
Hardware Installation Guide Version 1.4
Copyright c 20 10 ATOP Technologies, Inc.
All rights reserved
- 3 -
8. Pin assignment of Network Connections
10/100BaseT(X) Ethernet Port Connection
RJ-45
Pin
1
2
3
4
5
6
7
8
Signal
Tx+
Tx-
Rx+
Rx-
100BaseFx Fiber Cable Wring
-SC/ST Connectors
SC Connectors
ST Connecters
Fiber port
Single-Mode
Multi-mode
-Cable Wiring
TX
A
B
RX
ST Connector
RX
B
A
TX
TX
A
B
RX
SC Connector
RX
B
A
TX
Terminal Block for Power input
FG
Vin-
Vin+
Pin
Vin+
Vin-
FG
Signal
DC9-30V
0V
Frame Ground