Atomic Reactor 50-112 Скачать руководство пользователя страница 8

 



 

Remove the template 

frame of the DS- 1 

 

 
 

 
 

Still got the screws?

 

           



 

Replace the template 

frame with a blank 
template (Atomic Part # 

ATBLANK –  purchased 
separately).  

 

 
 

 
Still got the screws?

 

          



 

Replace the 8 screws. 

(Whew!)

 You can now 

load the DS-1 into the 

Reactor as usual *. 

 
The Reactor is now 

ready to be used with a 
Pro-rack or foot 

controller style modeler

 

 

 

NOTE!  When  bypassing  the  DS-1 , th e “R ETU R N ” in pu t on  th e rear 
jack  panel  of  the  Reactor  50  112/212  should  be  used  as  the 

R eactor’s m ain  in pu t, (see p ag es 1 1 -14).  Inserting  a  jack  into  the 

R ETU R N  p u ts th e R eactor in  “D irect M od e” an d  au tom atically can cels 
out the open audio cables from the DS-1. 

 

Return the DS-1 into it’s place in the A tom ic A m p w ith  a snap –  and that’s it! 

 

Turn the Master-Volume-Control on the rear of the Atomic Amp down. Connect the 
amp  to  your  favourite  mains  socket.  Turn  on  the  Power  Switch  (red),  wait  the 

obligatory 30 seconds until the tubes are warm. Now turn the  Stand-By switch on 
(blue)  and  adjust  the  gain  level  on  the  Master-Volume  the  Atomic  Amp  and  your 

Modeler and you will hear those fantastic warm, crisp Guitar/Amp sounds blow your 

tootsies off!  
 

For Rich Kids: If you want a really professional stereo solution, buy a second Atomic 
Reactor amp. Connect the Send-R-Output from the first Atomic Amp (the one with 

the Modeler!) with the Return-Jack on the rear of the second Atomic Amp.  

 
 

 
 

Содержание Reactor 50-112

Страница 1: ...Reactor 50 112 50 212 Owners Manual Copyright 2006 by G66 GmbH...

Страница 2: ...tem that is wide range and smooth no sharp peaks or ragged response The cabinet features a unique dual flared port and a closed back The unique design of the speaker cabinet coupled with the dynamic a...

Страница 3: ...d complete with a DS 1 docking unit and the following items 1 Owners Manual 2 Product Registration Card Packed with the DS 1 1 One 1 AC line cable for proper usage in the country of purchase 2 Three 3...

Страница 4: ...cords You should have received the right Template Kit for your modeler This Kit together with the Docking Station DS 1 and your Desktop Modeler will form a complete unit The power and audio connectio...

Страница 5: ...frame and the appropriate mounting hardware to hold a modeler securely in place inside the DS 1 docking unit The kit also includes the proper power connecting cable for the modeler to allow the modele...

Страница 6: ...frame Tighten down the thumbscrews until modeler is held securely in place After securing modeler connect the Input and Left Right output connectors The Input cable is extra long to accommodate modele...

Страница 7: ...of the Atomic Reactor Effect Loop on the rear side The signal is mono until a cable is put into the Send R Jack If you use a multi effect device or just plain old stomp machines they can be connected...

Страница 8: ...ati cal l y cancel s out the open audio cables from the DS 1 Return the DS 1 i nto i t s pl ace i n the A tom i c A m p w i th a snap and that s i t Turn the Master Volume Control on the rear of the A...

Страница 9: ...y located in the top of Reactor 1 making sure that the dock locks click into position Install a blank template onto the R eactor 2 s D S 1 Then load the DS 1 back into the Reactor Run a standard shiel...

Страница 10: ...e top of the Reactors making sure that the dock locks click into position Plug the Left and Right outputs of your Foot Controller style modeler or preamp into the pair of R eactor s R ETU R N inputs I...

Страница 11: ...the dock locks click into position Plug the Left and Right outputs of your Pro Rack style modeler or preamp into the pair of R eactor s R ETU R N inputs If using outboard effects pedals or devices wi...

Страница 12: ...ied professional Service Engineer to do it Inside the amplifier there are high voltages up to 400 Volt being used If one of the tubes should fail always replace both tubes at the same time Always use...

Отзывы: