III. CONNECTION TO COLD WATER LINE

 

ATTENTION:  ensure  that  the  filter  is  connected  to  a  cold  water  line  (t

max

  is  38

о

C). 

Connection to a hot water line will damage the filter.

 

 
1.  Close  the  valve  that  shuts  cold  water  off.  Open  the  cold 
water  tap  on  a  basin  mixer  to  depressurize  the  line.  If  water 
still flows from the tap even after valve closing, you have to 
close the main valve in the house or apartment. 

2.  The  system  is  connected  to  the  water  supply  line  via  the 
water supply unit. 

 

The  filter  set  may  include  the  combined  water  supply  unit  – 
T-tap. In this case ref. clause 2.4. 

2.1.  Assemble  the  water  supply  unit  by  connecting  the  ball 
valve with the T-piece as shown in 

Fig. 8

. Using PFTE tape, 

screw  the  T-piece  in  the  tap.  Be  especially  careful  while 
connecting  the  tap  -  excessive  force  will  damage  its  thread. 
Use  only  a  small  spanner  or  wrench.  Do  not  use  other 
materials to seal connections. 

2.2. Loosen the cap nut and disconnect the flexible line from 
the basin mixer. 

2.3. If necessary, replace the gasket of the cap nut. 

2.4.  Install  the  assembled  unit  in  the  flexible  line  from  the 
basin mixer, as shown in 

Fig. 9

. Use a spanner or a wrench. 

2.5. Connect the red tube to the filter (ref. Table on page 12) 
and to the ball valve. 

2.6. Close the tap at the inlet of the filtration unit and open the 
ball valve. Check connections for leaks. 

 

 

 

Fig. 8 

 

 

Fig. 9 

 

Содержание A-550 box STD

Страница 1: ...0 box STD OPERATION MAINTENANCE This system is assembled according to Specification TU 3697 009 58968054 2012 serial manufacturing It is tested by Main Center on Potable Water Control and Testing RU 0...

Страница 2: ...eproduce this manual in any mode in full or in part without the prior written consent of Rusfilter Scientific and Production Association Ltd Although all the necessary steps have been taking to verify...

Страница 3: ...y rules Water treatment layout using Atoll reverse osmosis filter Fig 1 1 Mechanical preliminary filter 2 Carbon preliminary filter 3 Fine filter 4 Membrane 5 Carbon post filter 6 Shutoff valve 7 Pure...

Страница 4: ...filter Cation exchange filter Anion exchange filter Micro filtration Reverse osmosis Solids 1 m Water hardness cal cium and magnesium Iron and manganese Copper lead and cadmium Fluorides Chlorides Chl...

Страница 5: ...2 water supply faucet 3 T piece 4 drain clamp 5 three colored tubes black dark blue and red 2 meters long each 6 membrane 7 PTFE tape brackets to prevent accidental disconnection they may be installe...

Страница 6: ...ion in other place with different quality of initial water After replacing a membrane or replaceable elements If the quality of water being treated is unknown it is desirable to analyze treated water...

Страница 7: ...valve at the tube used to supply water to the filter Service life of Atoll reverse osmotic filter is 5 years Although Atoll reverse osmotic filter intercepts all bacteria and viruses contained in wate...

Страница 8: ...orse than the above ones it is desirable to install additional water treatment system Consult your dealer or service center concerning its structure I CONNECTING TUBES USING QUICK RELEASE CONNECTORS A...

Страница 9: ...e ring near its basis 4 Pull the tube out while keeping the ring pressed Fig 4 Fig 4 We would like to pay your attention to the need to check the connection tightness before installation of filters Du...

Страница 10: ...iltration unit Nothing will hinder the tube connection to the pure water faucet from underside of a table board or sink Fig 5 Fig 6 The pure water faucet is installed according to Fig 5 We recommend n...

Страница 11: ...e 2 4 2 1 Assemble the water supply unit by connecting the ball valve with the T piece as shown in Fig 8 Using PFTE tape screw the T piece in the tap Be especially careful while connecting the tap exc...

Страница 12: ...filtration unit Description Pure water faucet Dark blue Faucet Pure water to the faucet Water supply unit Red Feed water Incoming water to osmotic treatment Drain clamp Black Drain water Water draina...

Страница 13: ...nding on the input water pressure DO NOT DRINK WATER OBTAINED DURING THE FIRST RESERVOIR FILLINGS 9 Install the top and back covers of the filtration unit Screw a self tapping screw into the back wall...

Страница 14: ...its service life are to be disposed as solid domestic wastes Recommended replacement intervals for expendable components Preliminary filters every 6 months Membrane every 24 30 months Carbon post fil...

Страница 15: ...d from it within one two weeks Low output Low inlet water pressure This system needs inlet pressure at least 2 8 atm If the pressure in your water supply system is less the above value it is necessary...

Страница 16: ...ew the connector clean or replace the valve Water is not supplied from the reservoir to the faucet Pressure in the storage reservoir is below the permissible value Pump air via the air valve of the st...

Страница 17: ...9 Chlorbrnzene 99 Chrome 97 Dichlrethane 99 Lead 99 Tetrachloroethylene 99 Filter specification Model A 550 box STD Treated water output at water salinity level 250 mg L temperature 15 pressure 3 5 at...

Страница 18: ...on with a high pressure transducer installed into the tube upstream the storage reservoir Transducer is necessary to ensure pump operation only during reservoir filling We also recommend installation...

Страница 19: ...s necessary to install Viqua SC1 2 UV lamp in the dark blue tube between the pure water faucet and the storage reservoir Fig 15 The lamp is attached to any surface using two clamps Fig 15 Connection t...

Отзывы: