background image

Matters need attention

A. Please read this instruction manual before using the detector.

B. The detector must be used in compliance with the designated procedures of our company.

C. The warranty period of this transmitter is 12months (starts from the date userget the detector). 

Users should comply with the instructionsin the use of this detector. Any damages or malfunctions 

caused by improperoperation of users are not within the scope of warranty.

D. Repairand replacement of any parts must be operated by trained sta

ff u

nder authorization of 

our company, using original spare part. The operatoris responsible for the liability if users operate 

the repair of replacement by themselves.

E. There is acid solution inside the transmitter, please do not disassembleit. And pay attention not 

to damage the frontal membrane of the transmitter. If the skin is stained with the acid solution. the 

right remedy is to flushing the stained skin continuously with clean water for 1 0minutes.

F. The detector must be calibrated for once each year. The explosion proof sheet parts of the 

transmitter need to be cleaned regularly (blow with low pressure compressedair), otherwise the 

detection sensitivity will be a

ected by the dust and impurities clogging protection hole.

3

2

1.Power supply, signal line

2.Printed-circuit board

3.Terminal

4.Sound and tight alarm port

5.Air chamber of sensor

6.Sensor port

7.Main board connection

Ground

connection port

5

6

1

2

3

4

7

1. Key Technical Indicator

Repeatability: <2%

Zero drift: < ± 2% (F•S) /6M

Operating temperature: -20~+50

Environment temperature: <90%RH

Working principle of the transmitter: electrochemical for oxygen and hazardous gases, catalytic 

combustion for combustible gases

Lifespan of transmitter: 3years for combustible gas transmitter; 2years for hazardous gas 

transmitter

2. Other Technical Parameters

Inspection mode: di

usion

Working mode: fixed long-term continuous work

Working voltage: 12-30V DC

Working current: oxygen and hazardous gas <50mA (Max)

combustible gas <150mA (Max)

Technical performance and parameters

Notice to Reader

Please read this instruction manual before using the detector

Output signal: three-wire 4-20 mA standard signal output or RS485 signal output

Exterior structure: die-casting aluminum housing

Dimensions: 135 x 125 x 116mm (without mounting bracket)

                      167 x 145 x 126mm (with bracket)

Weight: without mounting brackets 1.2kg with brackets 1.6kg with stent

Connection cable (6 core cable) is defined as follows:

4-20mA with RS485:

Red: positive-input of power (12 to 24V)/ 24V+

Black: ground wire of power/24V

Yellow:4-20mA output.

Orange: RS485A

Blue: RS485B

Brown: Free

Connection distance: >1000m

Protection grade: IP65

Installation type: on wall

Type of explosion-proof: flame proof

Explosion-proof grade: Ex d IIC T6 Gb

Inlet port: hexagonal locknut

Settings of Remote Control

The remote control applied to all product type produced by Yuante.

1. Press "MENU" once to enter F01, address code setting menu. Press "OK" to modify, press"+""-

"to modify address code of the detector. Press "OK" to save settings and "BACK" to cancel.

2. Press "MENU", then press “+”to enter F02, minimum value setting menu of gas alarm, Press 

"OK" to modify, press"+" "-"to modify the value. Press "OK" to save settings and "BACK" to 

cancel.

3. Continue to press "+"to enter F03, maximum value setting menu of gas alarm., Press "OK" to 

modify, press"+" "-"to modify the value. Press "OK" to save settings and "BACK" to cancel. Same 

operation with F04 (zero point calibration), F05 (range calibration), F06 (AD value).

4. Press "MENU" four times to enter a shift status, under this status:

Press "RESET" once, the data would be 255, one more it would be 0. Just press "RESET" to shift. 

When the data is 0, press "+"or"-"to modify alarm point, the data di

erence would be only 1. When 

the data is 255, press "+"or"-"to modify alarm point, the data di

erence would be 1000. "RESET" 

can also be used as mute button when it is alarming.

1

4

Fixed Gas Detector

YT-95H-:XX

Instruction Manual

Target gas

Range

Accuracy

least count

response time

O

2

0-30%VOL

<±2%(F.S)

0.01%VOL

15

H

2

S

0-1000ppm

<±2%(F.S)

1ppm

15

CO

0-1000ppm

<±2%(F.S)

1ppm

25

H

2

0-20000ppm

<±2%(F.S)

1ppm

15

CO

2

0-10000ppm

<±2%(F.S)

1ppm

40

C

2

H

4

0-100ppm

<±2%(F.S)

0.01ppm

60

NO

2

0-20.0ppm

<±2%(F.S)

0.1ppm

25

N

2

0-100%VOL

<±2%(F.S)

0.01%VOL

40

TVOC

0-6000ppm

<±2%(F.S)

1ppm

60

NH

3

0-100ppm

<±2%(F.S)

0.01ppm

40

ASH

3

0-10.00ppm

<±2%(F.S)

0.01ppm

30

C

3

H

3

N

0-200.0ppm

<±2%(F.S)

0.1ppm

40

F

2

0-10 ppm

<±2%(F.S)

0.01ppm

25

O

3

0-5.00ppm

<±2%(F.S)

0.01ppm

50

CL

2

0-10.00ppm

<±2%(F.S)

0.01ppm

60

BF

3

0-10.00ppm

<±2%(F.S)

0.01ppm

60

NC:Normally close
NO:Normally open
COM:Common
24V:24+,positive
GND:24-,negative
4~20mA:4~20mA analog signal

H

ig

A

la

rm

Lo

A

la

rm

R

el

ay

R

el

ay

Po

w

er

ed

Si

gn

al o

ut

pu

t

Motherboard connector

Alarm

Digital probe port

Digital probe port

Port Instruction

www.ato.com

[email protected]

18005851519

  

Global Shipping

www.ato.com

[email protected]

18005851519

  

Global Shipping

www.ato.com

[email protected]

18005851519

  

Global Shipping

www.ato.com

[email protected]

18005851519

  

Global Shipping

Отзывы: