background image

 

 

Welcome to visit ATO.com 

Tel: 800-585-1519      Email: [email protected]    Web

www.ato.com

 

Operation Interface 

When the detector is turned on completely, the device will enter the detecting mode. The detected gases will 

be showed on the screen (for example: O2, CO, H2S, EX). Time and battery power will be showed at the top 

right. If measured 4 gases, the time and battery power information can be checked by short press the ON/OFF 

button. 

 

Alarm Status 

When the detected gas concentration is higher than the low alarm value, the low alarm is auto on, the relative 

gas value will be highlighted, and the alarm sound will be on, blue light will be flickered.   

When the detected gas concentration is high than the high alarm value, the high alarm is auto on, the relative 

gas value will be highlighted, and the alarm sound will be on, red light will be flickered. 

When there is low alarm and high alarm at the same time, both relative gas values will be highlighted, and high 

alarm will take the priority. 

 

Low Battery Alarm 

When the battery is low, there will be sound, light low battery alarm. There will be sound and light every 5 

seconds to remind the user to charge the device in time. When the battery is used up, the device will be turned 

off automatically. 

 

 

Alarm Setting 

In detection model, long press “UP” button to enter the menu, choose the “Alarm point”, and start to set the 

alarm value.   

There are four options under the alarm setting mode. The first option is the “channel”, there will be 4 channels 

for 4 in 1 multi gas detector.   

Channel choose:

 press “ON/OFF” button, the cursor will be at the channel number, then press the “UP” and 

“DOWN” button to choose the channel, press the “ON/OFF” button to confirm. 

Alarm setting:

 The second option is the low alarm value, and the third option is the high alarm value. Choose 

the option that you want to change, then press “ON/OFF” to confirm, then press the “UP” and “DWON” to 

increase or decrease the value, press the “ON/OFF” to move cursor. After the setting is done, press “ON/OFF” 

button to save the settings. 

 

Settings 

In detection model, long press “UP” button to enter the menu, choose the “INST Setup”, and start to set the 

detector. 

There are three options: Language, gray level, LCD backlight. 

Language: Chinese and English are available. 

www.ato.com

 

Содержание YT-1200H-S4

Страница 1: ...et any data please remember to click ON OFF button to confirm and save the settings Power On Press the ON OFF for three seconds the detector will be turned on The screen displays the following interface successively Brand and Logo main parameter interface initialing countdown The countdown would be 30 60 seconds which is to make sure that the sensors are fully activated After 30 seconds the device...

Страница 2: ... until the reading back to zero before powering it off and do the zero point calibration next time before using it If the reading maintained at full scale user should send the device back to manufacturer or agent for repair or replacing the sensor Alarm light Silicon rubber case LCD USB charging port UP DOWN ON OFF Sensor air chamber Note If detector is used for the gas cylinder detection consider...

Страница 3: ...there will be sound light low battery alarm There will be sound and light every 5 seconds to remind the user to charge the device in time When the battery is used up the device will be turned off automatically Alarm Setting In detection model long press UP button to enter the menu choose the Alarm point and start to set the alarm value There are four options under the alarm setting mode The first ...

Страница 4: ... Prepare the standard gas before starting the target point calibration Choose standard gas press ON OFF button to enter There will show please input standard gas at the top of the LCD and at the bottom there are gas type calibrate value VA current concentration AD and ESC or SET Change the target concentration to the standard gas concentration by press UP and DOWN after the value is stable press t...

Отзывы: